An overview of methods for eliminating the effects of interference in an active high-voltage power facility

In this paper, practical and conceptual problems related to the way of suppressing or eliminating the influence of interference (at a frequency of 50 Hz) in an active high-voltage power facility are discussed. The problem is relevant in the context of measuring the safety characteristics of the grou...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Kostić Vojin I.
Formato: article
Lenguaje:EN
SR
Publicado: Savez inženjera i tehničara Srbije 2021
Materias:
Acceso en línea:https://doaj.org/article/bbcf679410764d0489100d320820c1f4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:bbcf679410764d0489100d320820c1f4
record_format dspace
spelling oai:doaj.org-article:bbcf679410764d0489100d320820c1f42021-12-05T21:39:59ZAn overview of methods for eliminating the effects of interference in an active high-voltage power facility0040-21762560-308610.5937/tehnika2104467Khttps://doaj.org/article/bbcf679410764d0489100d320820c1f42021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/0040-2176/2021/0040-21762104467K.pdfhttps://doaj.org/toc/0040-2176https://doaj.org/toc/2560-3086In this paper, practical and conceptual problems related to the way of suppressing or eliminating the influence of interference (at a frequency of 50 Hz) in an active high-voltage power facility are discussed. The problem is relevant in the context of measuring the safety characteristics of the grounding system: grounding system impedance, touch voltage and step voltage. The paper gives an evolutionary overview of title methods. The review focuses on the characteristic problems and shortcomings of individual methods. Also, the basic characteristics of the author's FSM (Frequency Shift Method) method, which guarantees precise control of interference, are elaborated. In this sense, the FSM method is the basis for accurate and economical measurement of the safety characteristics of the grounding system.Kostić Vojin I.Savez inženjera i tehničara Srbijearticlegroundinggrounding system testinginterferenceEngineering (General). Civil engineering (General)TA1-2040ENSRTehnika, Vol 76, Iss 4, Pp 467-472 (2021)
institution DOAJ
collection DOAJ
language EN
SR
topic grounding
grounding system testing
interference
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle grounding
grounding system testing
interference
Engineering (General). Civil engineering (General)
TA1-2040
Kostić Vojin I.
An overview of methods for eliminating the effects of interference in an active high-voltage power facility
description In this paper, practical and conceptual problems related to the way of suppressing or eliminating the influence of interference (at a frequency of 50 Hz) in an active high-voltage power facility are discussed. The problem is relevant in the context of measuring the safety characteristics of the grounding system: grounding system impedance, touch voltage and step voltage. The paper gives an evolutionary overview of title methods. The review focuses on the characteristic problems and shortcomings of individual methods. Also, the basic characteristics of the author's FSM (Frequency Shift Method) method, which guarantees precise control of interference, are elaborated. In this sense, the FSM method is the basis for accurate and economical measurement of the safety characteristics of the grounding system.
format article
author Kostić Vojin I.
author_facet Kostić Vojin I.
author_sort Kostić Vojin I.
title An overview of methods for eliminating the effects of interference in an active high-voltage power facility
title_short An overview of methods for eliminating the effects of interference in an active high-voltage power facility
title_full An overview of methods for eliminating the effects of interference in an active high-voltage power facility
title_fullStr An overview of methods for eliminating the effects of interference in an active high-voltage power facility
title_full_unstemmed An overview of methods for eliminating the effects of interference in an active high-voltage power facility
title_sort overview of methods for eliminating the effects of interference in an active high-voltage power facility
publisher Savez inženjera i tehničara Srbije
publishDate 2021
url https://doaj.org/article/bbcf679410764d0489100d320820c1f4
work_keys_str_mv AT kosticvojini anoverviewofmethodsforeliminatingtheeffectsofinterferenceinanactivehighvoltagepowerfacility
AT kosticvojini overviewofmethodsforeliminatingtheeffectsofinterferenceinanactivehighvoltagepowerfacility
_version_ 1718370969028919296