Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet
Abstract This study investigated the fluid–tissue interaction of needle-free injection by evaluating the dynamics of the cavity induced in body-tissue simulant and the resulting unsteady mechanical stress field. Temporal evolution of cavity shape, stress intensity field, and stress vector field duri...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/bca084f0d09449d4a94f94cf0e0ec0de |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:bca084f0d09449d4a94f94cf0e0ec0de |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:bca084f0d09449d4a94f94cf0e0ec0de2021-12-02T16:14:02ZDynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet10.1038/s41598-021-94018-62045-2322https://doaj.org/article/bca084f0d09449d4a94f94cf0e0ec0de2021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-94018-6https://doaj.org/toc/2045-2322Abstract This study investigated the fluid–tissue interaction of needle-free injection by evaluating the dynamics of the cavity induced in body-tissue simulant and the resulting unsteady mechanical stress field. Temporal evolution of cavity shape, stress intensity field, and stress vector field during the injection of a conventional injection needle, a proposed highly focused microjet (tip diameter much smaller than capillary nozzle), and a typical non-focused microjet in gelatin were measured using a state-of-the-art high-speed polarization camera, at a frame rate up to 25,000 f.p.s. During the needle injection performed by an experienced nurse, high stress intensity lasted for an order of seconds (from beginning of needle penetration until end of withdrawal), which is much longer than the order of milliseconds during needle-free injections, causing more damage to the body tissue. The cavity induced by focused microjet resembled a funnel which had a narrow tip that penetrated deep into tissue simulant, exerting shear stress in low intensity which diffused through shear stress wave. Whereas the cavity induced by non-focused microjet rebounded elastically (quickly expanded into a sphere and shrank into a small cavity which remained), exerting compressive stress on tissue simulant in high stress intensity. By comparing the distribution of stress intensity, tip shape of the focused microjet contributed to a better performance than non-focused microjet with its ability to penetrate deep while only inducing stress at lower intensity. Dynamic mechanical interaction revealed in this research uncovered the importance of the jet shape for the development of minimally invasive medical devices.Yuta MiyazakiMasashi UsawaShuma KawaiJingzu YeeMasakazu MutoYoshiyuki TagawaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-10 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Yuta Miyazaki Masashi Usawa Shuma Kawai Jingzu Yee Masakazu Muto Yoshiyuki Tagawa Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
description |
Abstract This study investigated the fluid–tissue interaction of needle-free injection by evaluating the dynamics of the cavity induced in body-tissue simulant and the resulting unsteady mechanical stress field. Temporal evolution of cavity shape, stress intensity field, and stress vector field during the injection of a conventional injection needle, a proposed highly focused microjet (tip diameter much smaller than capillary nozzle), and a typical non-focused microjet in gelatin were measured using a state-of-the-art high-speed polarization camera, at a frame rate up to 25,000 f.p.s. During the needle injection performed by an experienced nurse, high stress intensity lasted for an order of seconds (from beginning of needle penetration until end of withdrawal), which is much longer than the order of milliseconds during needle-free injections, causing more damage to the body tissue. The cavity induced by focused microjet resembled a funnel which had a narrow tip that penetrated deep into tissue simulant, exerting shear stress in low intensity which diffused through shear stress wave. Whereas the cavity induced by non-focused microjet rebounded elastically (quickly expanded into a sphere and shrank into a small cavity which remained), exerting compressive stress on tissue simulant in high stress intensity. By comparing the distribution of stress intensity, tip shape of the focused microjet contributed to a better performance than non-focused microjet with its ability to penetrate deep while only inducing stress at lower intensity. Dynamic mechanical interaction revealed in this research uncovered the importance of the jet shape for the development of minimally invasive medical devices. |
format |
article |
author |
Yuta Miyazaki Masashi Usawa Shuma Kawai Jingzu Yee Masakazu Muto Yoshiyuki Tagawa |
author_facet |
Yuta Miyazaki Masashi Usawa Shuma Kawai Jingzu Yee Masakazu Muto Yoshiyuki Tagawa |
author_sort |
Yuta Miyazaki |
title |
Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
title_short |
Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
title_full |
Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
title_fullStr |
Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
title_full_unstemmed |
Dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
title_sort |
dynamic mechanical interaction between injection liquid and human tissue simulant induced by needle-free injection of a highly focused microjet |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/bca084f0d09449d4a94f94cf0e0ec0de |
work_keys_str_mv |
AT yutamiyazaki dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet AT masashiusawa dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet AT shumakawai dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet AT jingzuyee dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet AT masakazumuto dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet AT yoshiyukitagawa dynamicmechanicalinteractionbetweeninjectionliquidandhumantissuesimulantinducedbyneedlefreeinjectionofahighlyfocusedmicrojet |
_version_ |
1718384372132872192 |