An Experimental Study of Capillary Tubes Behavior With R-12 and R-134a

Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature dr...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Hani A.Jasim, Issam M.Ali
Format: article
Langue:EN
Publié: Al-Khwarizmi College of Engineering – University of Baghdad 2005
Sujets:
Accès en ligne:https://doaj.org/article/bdd1fe9cc72043eb9bb5500f66a1307c
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
Description
Résumé:Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature drop across the capillary tube. While the speed of evaporator fan has small effect. Experimental results showed that the temperature gradient for the two refrigerants are the same, but after approximatly one meter the temperature gradient of R-134a is steeper than R-12.