Experimental assessment of harmonic contributions using a ternary pulse sequence
Harmonic contributions of utility and customer may feature significant variations due to network switchings and changing operational modes. In order to correctly define the impacts on the grid voltage distortion the frequency dependent impedance characteristic of the studied network should...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Faculty of Technical Sciences in Cacak
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/bdfd607979ed4426aae20f7cdeacfb04 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:bdfd607979ed4426aae20f7cdeacfb04 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:bdfd607979ed4426aae20f7cdeacfb042021-12-01T13:00:47ZExperimental assessment of harmonic contributions using a ternary pulse sequence1451-48692217-718310.2298/SJEE2103271Bhttps://doaj.org/article/bdfd607979ed4426aae20f7cdeacfb042021-01-01T00:00:00Zhttp://www.doiserbia.nb.rs/img/doi/1451-4869/2021/1451-48692103271B.pdfhttps://doaj.org/toc/1451-4869https://doaj.org/toc/2217-7183Harmonic contributions of utility and customer may feature significant variations due to network switchings and changing operational modes. In order to correctly define the impacts on the grid voltage distortion the frequency dependent impedance characteristic of the studied network should be accurately measured in the real-time mode. This condition can be fulfilled by designing a stimuli generator measuring the grid impedance as a response to injected interference and producing time-frequency plots of harmonic contributions during considered time interval. In this paper a prototype of a stimuli generator based on programmable voltage source inverter is developed and tested. The use of ternary pulse sequence allows fast wide-band impedance measurements that meet the requirements of real-time assessment of harmonic contributions. The accuracy of respective analysis involving impedance determination and calculation of harmonic contributions is validated experimentally using reference characteristics of laboratory test set-up with varying grid impedance.Bulycheva EvgeniiaYanchenko SergeyFaculty of Technical Sciences in Cacakarticleharmonic identificationharmonic contributionimpedance measurementnon-linear loadpower qualityternary pulse sequenceElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENSerbian Journal of Electrical Engineering, Vol 18, Iss 3, Pp 271-289 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
harmonic identification harmonic contribution impedance measurement non-linear load power quality ternary pulse sequence Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
harmonic identification harmonic contribution impedance measurement non-linear load power quality ternary pulse sequence Electrical engineering. Electronics. Nuclear engineering TK1-9971 Bulycheva Evgeniia Yanchenko Sergey Experimental assessment of harmonic contributions using a ternary pulse sequence |
description |
Harmonic contributions of utility and customer may feature significant
variations due to network switchings and changing operational modes. In
order to correctly define the impacts on the grid voltage distortion the
frequency dependent impedance characteristic of the studied network should
be accurately measured in the real-time mode. This condition can be
fulfilled by designing a stimuli generator measuring the grid impedance as a
response to injected interference and producing time-frequency plots of
harmonic contributions during considered time interval. In this paper a
prototype of a stimuli generator based on programmable voltage source
inverter is developed and tested. The use of ternary pulse sequence allows
fast wide-band impedance measurements that meet the requirements of
real-time assessment of harmonic contributions. The accuracy of respective
analysis involving impedance determination and calculation of harmonic
contributions is validated experimentally using reference characteristics of
laboratory test set-up with varying grid impedance. |
format |
article |
author |
Bulycheva Evgeniia Yanchenko Sergey |
author_facet |
Bulycheva Evgeniia Yanchenko Sergey |
author_sort |
Bulycheva Evgeniia |
title |
Experimental assessment of harmonic contributions using a ternary pulse sequence |
title_short |
Experimental assessment of harmonic contributions using a ternary pulse sequence |
title_full |
Experimental assessment of harmonic contributions using a ternary pulse sequence |
title_fullStr |
Experimental assessment of harmonic contributions using a ternary pulse sequence |
title_full_unstemmed |
Experimental assessment of harmonic contributions using a ternary pulse sequence |
title_sort |
experimental assessment of harmonic contributions using a ternary pulse sequence |
publisher |
Faculty of Technical Sciences in Cacak |
publishDate |
2021 |
url |
https://doaj.org/article/bdfd607979ed4426aae20f7cdeacfb04 |
work_keys_str_mv |
AT bulychevaevgeniia experimentalassessmentofharmoniccontributionsusingaternarypulsesequence AT yanchenkosergey experimentalassessmentofharmoniccontributionsusingaternarypulsesequence |
_version_ |
1718405198037123072 |