Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors
Abstract The study was aimed to evaluate the performance of a newly developed non-invasive and non-contact bilirubin measurement device (AJO-Neo) as an alternative to the conventional invasive biochemical method of total serum bilirubin (TSB) estimation in preterm and term neonates suffering from hy...
Guardado en:
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/bf89adfa73f54e93b93f1217354cbeb5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:bf89adfa73f54e93b93f1217354cbeb5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:bf89adfa73f54e93b93f1217354cbeb52021-12-02T15:39:58ZLarge scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors10.1038/s41598-020-67981-92045-2322https://doaj.org/article/bf89adfa73f54e93b93f1217354cbeb52020-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-67981-9https://doaj.org/toc/2045-2322Abstract The study was aimed to evaluate the performance of a newly developed non-invasive and non-contact bilirubin measurement device (AJO-Neo) as an alternative to the conventional invasive biochemical method of total serum bilirubin (TSB) estimation in preterm and term neonates suffering from hyperbilirubinemia associated with risk factors, and/or undergoing phototherapy. The safety and efficacy of the device were assessed in 1968 neonates with gestational ages ranging from 28 to 41 weeks and suffering from incidences of hyperbilirubinemia. Linear regression analysis showed a good correlation between AJO-Neo and the conventional method of TSB (Pearson’s coefficient, r = 0.79). The small bias (0.27 mg/dL) and limits of agreements (− 3.44 to 3.99 mg/dL) were within the range of clinical acceptance. The device was also precise in the measurement of bilirubin levels in all subgroups of the study. The receiver operator curve (ROC), that takes account of both sensitivity and specificity of a device showed high efficacy of the device (area under the curve, AUC = 0.83) in the detection of bilirubin. While monitoring the bilirubin level during phototherapy, the device indicated promising results showing good agreement with TSB. Specificities and sensitivities of the device indicated a much higher accuracy in neonates with associated risk factors for hyperbilirubinemia. Hence, the newly developed device (AJO-Neo) is reliable in measuring bilirubin level in preterm, and term neonates irrespective of gestational or postnatal age, sex, risk factors, feeding behavior or skin color.Animesh HalderAniruddha AdhikariRia GhoshSoumendra SinghAmrita BanerjeeNilanjana GhoshArnab Madhab BhattacharyaShrabani MandalPrantar ChakrabartiDebasis BhattacharyyaHatem M. AltassMoataz MoradSaleh A. AhmedAsim Kumar MallickSamir Kumar PalNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-14 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Animesh Halder Aniruddha Adhikari Ria Ghosh Soumendra Singh Amrita Banerjee Nilanjana Ghosh Arnab Madhab Bhattacharya Shrabani Mandal Prantar Chakrabarti Debasis Bhattacharyya Hatem M. Altass Moataz Morad Saleh A. Ahmed Asim Kumar Mallick Samir Kumar Pal Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
description |
Abstract The study was aimed to evaluate the performance of a newly developed non-invasive and non-contact bilirubin measurement device (AJO-Neo) as an alternative to the conventional invasive biochemical method of total serum bilirubin (TSB) estimation in preterm and term neonates suffering from hyperbilirubinemia associated with risk factors, and/or undergoing phototherapy. The safety and efficacy of the device were assessed in 1968 neonates with gestational ages ranging from 28 to 41 weeks and suffering from incidences of hyperbilirubinemia. Linear regression analysis showed a good correlation between AJO-Neo and the conventional method of TSB (Pearson’s coefficient, r = 0.79). The small bias (0.27 mg/dL) and limits of agreements (− 3.44 to 3.99 mg/dL) were within the range of clinical acceptance. The device was also precise in the measurement of bilirubin levels in all subgroups of the study. The receiver operator curve (ROC), that takes account of both sensitivity and specificity of a device showed high efficacy of the device (area under the curve, AUC = 0.83) in the detection of bilirubin. While monitoring the bilirubin level during phototherapy, the device indicated promising results showing good agreement with TSB. Specificities and sensitivities of the device indicated a much higher accuracy in neonates with associated risk factors for hyperbilirubinemia. Hence, the newly developed device (AJO-Neo) is reliable in measuring bilirubin level in preterm, and term neonates irrespective of gestational or postnatal age, sex, risk factors, feeding behavior or skin color. |
format |
article |
author |
Animesh Halder Aniruddha Adhikari Ria Ghosh Soumendra Singh Amrita Banerjee Nilanjana Ghosh Arnab Madhab Bhattacharya Shrabani Mandal Prantar Chakrabarti Debasis Bhattacharyya Hatem M. Altass Moataz Morad Saleh A. Ahmed Asim Kumar Mallick Samir Kumar Pal |
author_facet |
Animesh Halder Aniruddha Adhikari Ria Ghosh Soumendra Singh Amrita Banerjee Nilanjana Ghosh Arnab Madhab Bhattacharya Shrabani Mandal Prantar Chakrabarti Debasis Bhattacharyya Hatem M. Altass Moataz Morad Saleh A. Ahmed Asim Kumar Mallick Samir Kumar Pal |
author_sort |
Animesh Halder |
title |
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
title_short |
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
title_full |
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
title_fullStr |
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
title_full_unstemmed |
Large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
title_sort |
large scale validation of a new non-invasive and non-contact bilirubinometer in neonates with risk factors |
publisher |
Nature Portfolio |
publishDate |
2020 |
url |
https://doaj.org/article/bf89adfa73f54e93b93f1217354cbeb5 |
work_keys_str_mv |
AT animeshhalder largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT aniruddhaadhikari largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT riaghosh largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT soumendrasingh largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT amritabanerjee largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT nilanjanaghosh largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT arnabmadhabbhattacharya largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT shrabanimandal largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT prantarchakrabarti largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT debasisbhattacharyya largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT hatemmaltass largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT moatazmorad largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT salehaahmed largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT asimkumarmallick largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors AT samirkumarpal largescalevalidationofanewnoninvasiveandnoncontactbilirubinometerinneonateswithriskfactors |
_version_ |
1718385896985722880 |