Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads
One way to improve a structure’s total load-bearing capacity during an earthquake is to apply fiber-reinforced polymers (FRP) to unreinforced walls. The study discusses the use of FRP to strengthen unreinforced masonry (URM) structures. Although, many studies were conducted on the FRP strengthening...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/c07c11cc446a400ea2b1b6f6871e811d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:c07c11cc446a400ea2b1b6f6871e811d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:c07c11cc446a400ea2b1b6f6871e811d2021-11-25T17:00:40ZAssessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads10.3390/buildings111105592075-5309https://doaj.org/article/c07c11cc446a400ea2b1b6f6871e811d2021-11-01T00:00:00Zhttps://www.mdpi.com/2075-5309/11/11/559https://doaj.org/toc/2075-5309One way to improve a structure’s total load-bearing capacity during an earthquake is to apply fiber-reinforced polymers (FRP) to unreinforced walls. The study discusses the use of FRP to strengthen unreinforced masonry (URM) structures. Although, many studies were conducted on the FRP strengthening of URM buildings, most of them were experiments to investigate the success of retrofitting approaches, rather than developing a successful design model. A database of 120 FRP-reinforced wall samples was created based on the current literature. Various approaches for calculating the bearing capacity of FRP-reinforced masonry are presented and detailed. The findings of the experiments, which were compiled into a database, were compared to those derived using formulas from the literature and/or building codes, and the model’s limitations are discussed.Marijana Hadzima-NyarkoStanko ČolakBorko Đ. BulajićNaida AdemovićMDPI AGarticleunreinforced masonry (URM) wallsfiber-reinforced polymersbearing capacity of FRP-reinforced masonrydatabase of experimental resultsBuilding constructionTH1-9745ENBuildings, Vol 11, Iss 559, p 559 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
unreinforced masonry (URM) walls fiber-reinforced polymers bearing capacity of FRP-reinforced masonry database of experimental results Building construction TH1-9745 |
spellingShingle |
unreinforced masonry (URM) walls fiber-reinforced polymers bearing capacity of FRP-reinforced masonry database of experimental results Building construction TH1-9745 Marijana Hadzima-Nyarko Stanko Čolak Borko Đ. Bulajić Naida Ademović Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
description |
One way to improve a structure’s total load-bearing capacity during an earthquake is to apply fiber-reinforced polymers (FRP) to unreinforced walls. The study discusses the use of FRP to strengthen unreinforced masonry (URM) structures. Although, many studies were conducted on the FRP strengthening of URM buildings, most of them were experiments to investigate the success of retrofitting approaches, rather than developing a successful design model. A database of 120 FRP-reinforced wall samples was created based on the current literature. Various approaches for calculating the bearing capacity of FRP-reinforced masonry are presented and detailed. The findings of the experiments, which were compiled into a database, were compared to those derived using formulas from the literature and/or building codes, and the model’s limitations are discussed. |
format |
article |
author |
Marijana Hadzima-Nyarko Stanko Čolak Borko Đ. Bulajić Naida Ademović |
author_facet |
Marijana Hadzima-Nyarko Stanko Čolak Borko Đ. Bulajić Naida Ademović |
author_sort |
Marijana Hadzima-Nyarko |
title |
Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
title_short |
Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
title_full |
Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
title_fullStr |
Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
title_full_unstemmed |
Assessment of Selected Models for FRP-Retrofitted URM Walls under In-Plane Loads |
title_sort |
assessment of selected models for frp-retrofitted urm walls under in-plane loads |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/c07c11cc446a400ea2b1b6f6871e811d |
work_keys_str_mv |
AT marijanahadzimanyarko assessmentofselectedmodelsforfrpretrofittedurmwallsunderinplaneloads AT stankocolak assessmentofselectedmodelsforfrpretrofittedurmwallsunderinplaneloads AT borkođbulajic assessmentofselectedmodelsforfrpretrofittedurmwallsunderinplaneloads AT naidaademovic assessmentofselectedmodelsforfrpretrofittedurmwallsunderinplaneloads |
_version_ |
1718412800434372608 |