Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study

Wally auf der Strasse,1 Daniel Prado Campos,1 Celso Júnio Aguiar Mendonça,1 Jamil Faissal Soni,2 Joaquim Mendes,3 Percy Nohama1,2 1Universidade Tecnológica Federal do Paraná, Curitiba, Paraná, Brasil; 2Pontifícia Universidade Católica do Paraná, Curitiba, Paraná, Brasil; 3INEGI, Faculdade de Engenha...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: auf der Strasse W, Campos DP, Mendonça CJA, Soni JF, Mendes J, Nohama P
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/c0dabd8aefbc496cba0303aef6903c2f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c0dabd8aefbc496cba0303aef6903c2f
record_format dspace
spelling oai:doaj.org-article:c0dabd8aefbc496cba0303aef6903c2f2021-11-14T19:00:30ZEvaluation of Tibia Bone Healing by Infrared Thermography: A Case Study1178-2390https://doaj.org/article/c0dabd8aefbc496cba0303aef6903c2f2021-11-01T00:00:00Zhttps://www.dovepress.com/evaluation-of-tibia-bone-healing-by-infrared-thermography-a-case-study-peer-reviewed-fulltext-article-JMDHhttps://doaj.org/toc/1178-2390Wally auf der Strasse,1 Daniel Prado Campos,1 Celso Júnio Aguiar Mendonça,1 Jamil Faissal Soni,2 Joaquim Mendes,3 Percy Nohama1,2 1Universidade Tecnológica Federal do Paraná, Curitiba, Paraná, Brasil; 2Pontifícia Universidade Católica do Paraná, Curitiba, Paraná, Brasil; 3INEGI, Faculdade de Engenharia, Universidade do Porto, Porto, PortugalCorrespondence: Wally auf der Strasse Rua Omílio Monteiro Soares, 1360, Fanny, Curitiba, Paraná, CEP 81.030-001, BrasilTel +55 41 99974-6692Email wallystrasse@hotmail.comBackground: Thermal imaging has been used as a clinical follow-up technique in several medical specialties.Purpose: The aim of this study was to investigate the feasibility of using medical thermography in the diagnosis and follow-up assessment of a severe orthopedic trauma that requires the use of an external circular fixator.Patients and Methods: Twenty clinical follow-ups of thermal imaging correlated with X-ray images were performed in a male volunteer, diagnosed with bone nonunion, during 11 months of treatment, in the hospital trauma and reconstruction department. Data were acquired in the regions of interest of the proximal tibia, diaphysis and distal, with a Flir T530 medical grade infrared camera from Flir Systems®, and the data processed by the Matlab® 2019 custom made software.Results: Statistical analysis was performed by Wilcoxon signed-rank test. The results showed a median temperature of 22.2°C, and thus some periods of interruption in the healing process between the third and twentieth clinical follow-up, and a significant increase of the temperature to 34.6°C synchronous with a diagnosis of bone infection by the eleventh clinical follow-up. The thermal images acquired during the 20 clinical follow-ups allow a correlation with the data from the X-ray exams and also with the contralateral limb of the evaluated patient, showing thermal alterations greater than 0.3°C, which are significant of physiological abnormality.Conclusion: The thermography exam can be a useful tool for applying on the follow-up of patients after trauma or bone fracture. The results showed important physiological data related to the vascularization necessary for bone repairing, being therefore a good indicator of the healing process. In addition, as infrared thermography does not use ionizing radiation, it can be used countlessly, in complement to the traditional X-ray exams that focus on anatomical data analysis.Keywords: infrared medical thermography, nonunion, bone healing, Ilizarov methodauf der Strasse WCampos DPMendonça CJASoni JFMendes JNohama PDove Medical Pressarticleinfrared medical thermographynonunionbone healingilizarov methodMedicine (General)R5-920ENJournal of Multidisciplinary Healthcare, Vol Volume 14, Pp 3161-3175 (2021)
institution DOAJ
collection DOAJ
language EN
topic infrared medical thermography
nonunion
bone healing
ilizarov method
Medicine (General)
R5-920
spellingShingle infrared medical thermography
nonunion
bone healing
ilizarov method
Medicine (General)
R5-920
auf der Strasse W
Campos DP
Mendonça CJA
Soni JF
Mendes J
Nohama P
Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
description Wally auf der Strasse,1 Daniel Prado Campos,1 Celso Júnio Aguiar Mendonça,1 Jamil Faissal Soni,2 Joaquim Mendes,3 Percy Nohama1,2 1Universidade Tecnológica Federal do Paraná, Curitiba, Paraná, Brasil; 2Pontifícia Universidade Católica do Paraná, Curitiba, Paraná, Brasil; 3INEGI, Faculdade de Engenharia, Universidade do Porto, Porto, PortugalCorrespondence: Wally auf der Strasse Rua Omílio Monteiro Soares, 1360, Fanny, Curitiba, Paraná, CEP 81.030-001, BrasilTel +55 41 99974-6692Email wallystrasse@hotmail.comBackground: Thermal imaging has been used as a clinical follow-up technique in several medical specialties.Purpose: The aim of this study was to investigate the feasibility of using medical thermography in the diagnosis and follow-up assessment of a severe orthopedic trauma that requires the use of an external circular fixator.Patients and Methods: Twenty clinical follow-ups of thermal imaging correlated with X-ray images were performed in a male volunteer, diagnosed with bone nonunion, during 11 months of treatment, in the hospital trauma and reconstruction department. Data were acquired in the regions of interest of the proximal tibia, diaphysis and distal, with a Flir T530 medical grade infrared camera from Flir Systems®, and the data processed by the Matlab® 2019 custom made software.Results: Statistical analysis was performed by Wilcoxon signed-rank test. The results showed a median temperature of 22.2°C, and thus some periods of interruption in the healing process between the third and twentieth clinical follow-up, and a significant increase of the temperature to 34.6°C synchronous with a diagnosis of bone infection by the eleventh clinical follow-up. The thermal images acquired during the 20 clinical follow-ups allow a correlation with the data from the X-ray exams and also with the contralateral limb of the evaluated patient, showing thermal alterations greater than 0.3°C, which are significant of physiological abnormality.Conclusion: The thermography exam can be a useful tool for applying on the follow-up of patients after trauma or bone fracture. The results showed important physiological data related to the vascularization necessary for bone repairing, being therefore a good indicator of the healing process. In addition, as infrared thermography does not use ionizing radiation, it can be used countlessly, in complement to the traditional X-ray exams that focus on anatomical data analysis.Keywords: infrared medical thermography, nonunion, bone healing, Ilizarov method
format article
author auf der Strasse W
Campos DP
Mendonça CJA
Soni JF
Mendes J
Nohama P
author_facet auf der Strasse W
Campos DP
Mendonça CJA
Soni JF
Mendes J
Nohama P
author_sort auf der Strasse W
title Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_short Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_full Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_fullStr Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_full_unstemmed Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_sort evaluation of tibia bone healing by infrared thermography: a case study
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/c0dabd8aefbc496cba0303aef6903c2f
work_keys_str_mv AT aufderstrassew evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT camposdp evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT mendoncacja evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT sonijf evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT mendesj evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT nohamap evaluationoftibiabonehealingbyinfraredthermographyacasestudy
_version_ 1718429008100589568