Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients

Abstract Optical heart rate monitoring (OHR) with reflective wrist photoplethysmography is a technique mainly used in the wellness application domain for monitoring heart rate levels during exercise. In the absence of motion, OHR technique is also able to estimate individual beat-to-beat intervals r...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Christoph Hoog Antink, Yen Mai, Mikko Peltokangas, Steffen Leonhardt, Niku Oksala, Antti Vehkaoja
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/c298fdf64c8d46f692c3b57a5ce76ef5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c298fdf64c8d46f692c3b57a5ce76ef5
record_format dspace
spelling oai:doaj.org-article:c298fdf64c8d46f692c3b57a5ce76ef52021-12-02T18:03:15ZAccuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients10.1038/s41598-021-87489-02045-2322https://doaj.org/article/c298fdf64c8d46f692c3b57a5ce76ef52021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87489-0https://doaj.org/toc/2045-2322Abstract Optical heart rate monitoring (OHR) with reflective wrist photoplethysmography is a technique mainly used in the wellness application domain for monitoring heart rate levels during exercise. In the absence of motion, OHR technique is also able to estimate individual beat-to-beat intervals relatively well and can therefore also be used, for example, in monitoring of cardiac arrhythmias, stress, or sleep quality through heart rate variability (HRV) analysis. HRV analysis has also potential in monitoring the recovery of patients, e.g. after a medical intervention. However, in order to detect subtle changes, the calculated HRV parameters should be sufficiently accurate and very few studies exist that asses the accuracy of OHR derived HRV in non-healthy subjects. In this paper, we present a method to estimate beat-to-beat-intervals (BBIs) from reflective wrist PPG signal and evaluated the accuracy of the proposed method in estimating BBIs in a cross-sectional study with 29 hospitalized patients (mean age 70.6 years) in 24-h recordings performed after peripheral vascular surgery or endovascular interventions. Finally, we evaluate the accuracy of more than 30 commonly used HRV parameters and find that the accuracy of certain metrics, for example SDNN and triangular index, shown in the literature to be associated with the deterioration of the status of the patients during recovery from surgical intervention, could be adequate for patient monitoring. On the other hand, the parameters more affected by the high-frequency content of the HRV and especially the LF/HF-ratio should be used with caution.Christoph Hoog AntinkYen MaiMikko PeltokangasSteffen LeonhardtNiku OksalaAntti VehkaojaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Christoph Hoog Antink
Yen Mai
Mikko Peltokangas
Steffen Leonhardt
Niku Oksala
Antti Vehkaoja
Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
description Abstract Optical heart rate monitoring (OHR) with reflective wrist photoplethysmography is a technique mainly used in the wellness application domain for monitoring heart rate levels during exercise. In the absence of motion, OHR technique is also able to estimate individual beat-to-beat intervals relatively well and can therefore also be used, for example, in monitoring of cardiac arrhythmias, stress, or sleep quality through heart rate variability (HRV) analysis. HRV analysis has also potential in monitoring the recovery of patients, e.g. after a medical intervention. However, in order to detect subtle changes, the calculated HRV parameters should be sufficiently accurate and very few studies exist that asses the accuracy of OHR derived HRV in non-healthy subjects. In this paper, we present a method to estimate beat-to-beat-intervals (BBIs) from reflective wrist PPG signal and evaluated the accuracy of the proposed method in estimating BBIs in a cross-sectional study with 29 hospitalized patients (mean age 70.6 years) in 24-h recordings performed after peripheral vascular surgery or endovascular interventions. Finally, we evaluate the accuracy of more than 30 commonly used HRV parameters and find that the accuracy of certain metrics, for example SDNN and triangular index, shown in the literature to be associated with the deterioration of the status of the patients during recovery from surgical intervention, could be adequate for patient monitoring. On the other hand, the parameters more affected by the high-frequency content of the HRV and especially the LF/HF-ratio should be used with caution.
format article
author Christoph Hoog Antink
Yen Mai
Mikko Peltokangas
Steffen Leonhardt
Niku Oksala
Antti Vehkaoja
author_facet Christoph Hoog Antink
Yen Mai
Mikko Peltokangas
Steffen Leonhardt
Niku Oksala
Antti Vehkaoja
author_sort Christoph Hoog Antink
title Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
title_short Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
title_full Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
title_fullStr Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
title_full_unstemmed Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients
title_sort accuracy of heart rate variability estimated with reflective wrist-ppg in elderly vascular patients
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/c298fdf64c8d46f692c3b57a5ce76ef5
work_keys_str_mv AT christophhoogantink accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
AT yenmai accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
AT mikkopeltokangas accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
AT steffenleonhardt accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
AT nikuoksala accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
AT anttivehkaoja accuracyofheartratevariabilityestimatedwithreflectivewristppginelderlyvascularpatients
_version_ 1718378775473815552