Design and Construction of Electrical Magnate to Study its Efficiency and the Optimum Parameters to Produce Alkaline Magnetic Water and Treating the Sea Water to be Suitable for Irrigation

Abstract Electrical magnate  was designed and constructed,  the optimum Magnetic flux  and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studie...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Alaa Dhari Jawad Al-Bayati
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2015
Materias:
Acceso en línea:https://doaj.org/article/c2e547fe56894d4fa4f3bfb51f1faec6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract Electrical magnate  was designed and constructed,  the optimum Magnetic flux  and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studied, to simulate ZamZam water in Mekka Saudi Arabia. Also, the efficiency of magnetic field from this designed electrical magnate in decreasing the TDS of sea water (of 1500 ppm NaCl Content), to convert it to water suitable for irrigation (TDS<1000 ppm) was investigated in this work.The results show that the magnetic flux from our designed electrical magnate in the range of (0.013- 0.08) Tesla and 30 minutes magnetic treatment time is sufficient to produce alkaline water with pH similar to ZamZam water (pH from 7.85- 8). While 60 minutes of magnetic treatment results to higher values of pH and the maximum pH value of 8.9 is obtained when the magnetic flux is 0.026 Tesla. The investigation for reducing the TDS of water having 1500 ppm NaCl show that , the maximum decrease in TDS is took place when the magnetic flux is 0.013 Tesla(coil  of 100 turn and 1.5 V) and the time for magnetic treatment is 30 minutes where the TDS of 1730 ppm reduced to 1290 ppm is obtained .The effect  of magnetic treatment  on the pH  change of high NaCl content water  give maximum pH value of 8.1  when the magnetic flux  is 0.013 and 0.028 Tesla (the voltages is 1.5 & 3 V respectively  and 100 turn coil)  and the time period of magnetic treatment is 30 minutes.  The trend of results agreed well with previous studies, where the magnetic treatment lead always to increase of pH, decrease in TDS and electrical conductivity  Keywords: Electrical magnate, Magnetic water, alkaline water, Design of electrical magnate, TDS, pH, ZamZam water.