Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems
Abstract Objectives To compare intraoperative 3D fluoroscopy with a ceiling-mounted flat panel detector in plate osteosynthesis of distal radius fractures (AO/OTA 2R3C1.2) with volar locking plate systems to conventional 2D fluoroscopy for detection of insufficient fracture reduction, plate misplace...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
BMC
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/c3755d2bb7674e308c36664887a69fc8 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:c3755d2bb7674e308c36664887a69fc8 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:c3755d2bb7674e308c36664887a69fc82021-11-08T10:58:23ZComparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems10.1186/s12891-021-04784-71471-2474https://doaj.org/article/c3755d2bb7674e308c36664887a69fc82021-11-01T00:00:00Zhttps://doi.org/10.1186/s12891-021-04784-7https://doaj.org/toc/1471-2474Abstract Objectives To compare intraoperative 3D fluoroscopy with a ceiling-mounted flat panel detector in plate osteosynthesis of distal radius fractures (AO/OTA 2R3C1.2) with volar locking plate systems to conventional 2D fluoroscopy for detection of insufficient fracture reduction, plate misplacement and protruding screws. Methods Using a common volar approach on 12 cadaver forearms, total intraarticular distal radius fractures were induced, manually reduced and internally fixated with a 2.4 distal radius locking compression plate. 2D (anterior-posterior and lateral) and 3D (rotational) fluoroscopic images were taken as well as computed tomographies. Fluoroscopic images, Cone Beam CT (CBCT), 360° rotating sequences (so called “Movies”) and CT scans were co-evaluated by a specialist orthopedic surgeon and a specialist radiologist regarding quality of fracture reduction, position of plate, position of the three distal locking screws and position of the three diaphyseal screws. In reference to gold standard CT, sensitivity and specifity were analyzed. Results “Movie” showed highest sensitivity for detection of insufficient fracture reduction (88%). Sensitivity for detection of incorrect position of plate was 100% for CBCT and 90% for “Movie.” For intraarticular position of screws, 2D fluoroscopy and CBCT showed highest sensitivity and specifity (100 and 91%, respectively). Regarding detection of only marginal intraarticular position of screws, sensitivity and specifity of 2D fluoroscopy reached 100% (CBCT: 100 and 83%). “Movie” showed highest sensitivity for detection of overlapping position of screws (100%). When it comes to specifity, CBCT achieved 100%. Regarding detection of only marginal overlapping position of screws, 2D fluoroscopy and “Movie” showed highest sensitivity (100%). CBCT achieved highest specifity (100%). Conclusion As for assessment of quality of fracture reduction and detection of incorrect position of plate as well as overlapping position of the three diaphyseal screws CBCT and “Movie” are comparable to CT – especially when combined. Particularly sensitivity is high compared to standard 2D fluoroscopy.Raphael SeutheAndreas SeekampBodo KurzJulian PfarrJost Philipp SchaeferSimon PehSebastian LipprossBMCarticleDistal radius fractureInsufficient fracture reductionPlate misplacementScrew misplacementIntraarticular screwProtruding screwDiseases of the musculoskeletal systemRC925-935ENBMC Musculoskeletal Disorders, Vol 22, Iss 1, Pp 1-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Distal radius fracture Insufficient fracture reduction Plate misplacement Screw misplacement Intraarticular screw Protruding screw Diseases of the musculoskeletal system RC925-935 |
spellingShingle |
Distal radius fracture Insufficient fracture reduction Plate misplacement Screw misplacement Intraarticular screw Protruding screw Diseases of the musculoskeletal system RC925-935 Raphael Seuthe Andreas Seekamp Bodo Kurz Julian Pfarr Jost Philipp Schaefer Simon Peh Sebastian Lippross Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
description |
Abstract Objectives To compare intraoperative 3D fluoroscopy with a ceiling-mounted flat panel detector in plate osteosynthesis of distal radius fractures (AO/OTA 2R3C1.2) with volar locking plate systems to conventional 2D fluoroscopy for detection of insufficient fracture reduction, plate misplacement and protruding screws. Methods Using a common volar approach on 12 cadaver forearms, total intraarticular distal radius fractures were induced, manually reduced and internally fixated with a 2.4 distal radius locking compression plate. 2D (anterior-posterior and lateral) and 3D (rotational) fluoroscopic images were taken as well as computed tomographies. Fluoroscopic images, Cone Beam CT (CBCT), 360° rotating sequences (so called “Movies”) and CT scans were co-evaluated by a specialist orthopedic surgeon and a specialist radiologist regarding quality of fracture reduction, position of plate, position of the three distal locking screws and position of the three diaphyseal screws. In reference to gold standard CT, sensitivity and specifity were analyzed. Results “Movie” showed highest sensitivity for detection of insufficient fracture reduction (88%). Sensitivity for detection of incorrect position of plate was 100% for CBCT and 90% for “Movie.” For intraarticular position of screws, 2D fluoroscopy and CBCT showed highest sensitivity and specifity (100 and 91%, respectively). Regarding detection of only marginal intraarticular position of screws, sensitivity and specifity of 2D fluoroscopy reached 100% (CBCT: 100 and 83%). “Movie” showed highest sensitivity for detection of overlapping position of screws (100%). When it comes to specifity, CBCT achieved 100%. Regarding detection of only marginal overlapping position of screws, 2D fluoroscopy and “Movie” showed highest sensitivity (100%). CBCT achieved highest specifity (100%). Conclusion As for assessment of quality of fracture reduction and detection of incorrect position of plate as well as overlapping position of the three diaphyseal screws CBCT and “Movie” are comparable to CT – especially when combined. Particularly sensitivity is high compared to standard 2D fluoroscopy. |
format |
article |
author |
Raphael Seuthe Andreas Seekamp Bodo Kurz Julian Pfarr Jost Philipp Schaefer Simon Peh Sebastian Lippross |
author_facet |
Raphael Seuthe Andreas Seekamp Bodo Kurz Julian Pfarr Jost Philipp Schaefer Simon Peh Sebastian Lippross |
author_sort |
Raphael Seuthe |
title |
Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
title_short |
Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
title_full |
Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
title_fullStr |
Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
title_full_unstemmed |
Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
title_sort |
comparison of a ceiling-mounted 3d flat panel detector vs. conventional intraoperative 2d fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems |
publisher |
BMC |
publishDate |
2021 |
url |
https://doaj.org/article/c3755d2bb7674e308c36664887a69fc8 |
work_keys_str_mv |
AT raphaelseuthe comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT andreasseekamp comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT bodokurz comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT julianpfarr comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT jostphilippschaefer comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT simonpeh comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems AT sebastianlippross comparisonofaceilingmounted3dflatpaneldetectorvsconventionalintraoperative2dfluoroscopyinplateosteosynthesisofdistalradiusfractureswithvolarlockingplatesystems |
_version_ |
1718442467978641408 |