Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study

Background: Periodontal disease is an inflammatory process resulting in clinical attachment loss (CAL), pocket depth (PD), and resulting in the loss of alveolar bone. Diagnostic imaging provides an adjunctive guidelines to assess the alveolar bone height in addition to clinical parameters such as PD...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chaitanya Adurty, Kanikanti Siva Tejaswi, Cheruvu Ramya Naga Shivani, Didla Navya, Cheni Gopinath, Ravindranath Dhulipalla
Formato: article
Lenguaje:EN
Publicado: Wolters Kluwer Medknow Publications 2021
Materias:
Acceso en línea:https://doaj.org/article/c388273517b944ac96bb2873f153f927
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c388273517b944ac96bb2873f153f927
record_format dspace
spelling oai:doaj.org-article:c388273517b944ac96bb2873f153f9272021-11-12T10:23:42ZAccuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study0972-124X10.4103/jisp.jisp_518_20https://doaj.org/article/c388273517b944ac96bb2873f153f9272021-01-01T00:00:00Zhttp://www.jisponline.com/article.asp?issn=0972-124X;year=2021;volume=25;issue=6;spage=491;epage=495;aulast=Adurtyhttps://doaj.org/toc/0972-124XBackground: Periodontal disease is an inflammatory process resulting in clinical attachment loss (CAL), pocket depth (PD), and resulting in the loss of alveolar bone. Diagnostic imaging provides an adjunctive guidelines to assess the alveolar bone height in addition to clinical parameters such as PD and CAL. Aims and Objectives: The objectives of the study are to determine whether the digital intraoral periapical (IOPA) radiographs can be reliably used as an alternative to cone-beam computed tomography (CBCT) in the diagnosis of intrabony defects. Materials and Methods: A total of 25 patients with the presence of intrabony defects were included in the study. All the radiographic parameters were recorded using digital IOPA and CBCT. Various intrabony defect morphological characteristics such as height, depth, width, and angle were measured and compared between digital IOPA and CBCT. Statistics: The data was subjected to statistical analysis. Mann–Whitney U-test was performed for interexaminer comparison and independent t-test for intergroup comparison. Results: The mean intergroup comparison values between digital IOPA and CBCT in relation to defect width were 3.22 ± 1.10 and 3.20 ± 1.16, respectively (P = 0.970), in relation to defect depth were 7.71 ± 2.3 and 7.91 ± 2.4, respectively (P = 0.769), in relation to defect height were 3.80 ± 1.20 and 3.90 ± 1.2, respectively (P = 0.794), and in relation to defect angle were 34.82 ± 8.4 and 35.28 ± 0.8.6, respectively (P = 0.851). Conclusion: With the drawbacks of such as high radiation exposure, unavailability, and high financial cost, digital IOPA with digital software can be used as an alternative to CBCT for measuring intrabony defect morphological characteristics in periodontitis patients.Chaitanya AdurtyKanikanti Siva TejaswiCheruvu Ramya Naga ShivaniDidla NavyaCheni GopinathRavindranath DhulipallaWolters Kluwer Medknow Publicationsarticlecone-beam computed tomographydigital radiographsintrabony defectsperiodontitisDentistryRK1-715ENJournal of Indian Society of Periodontology, Vol 25, Iss 6, Pp 491-495 (2021)
institution DOAJ
collection DOAJ
language EN
topic cone-beam computed tomography
digital radiographs
intrabony defects
periodontitis
Dentistry
RK1-715
spellingShingle cone-beam computed tomography
digital radiographs
intrabony defects
periodontitis
Dentistry
RK1-715
Chaitanya Adurty
Kanikanti Siva Tejaswi
Cheruvu Ramya Naga Shivani
Didla Navya
Cheni Gopinath
Ravindranath Dhulipalla
Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
description Background: Periodontal disease is an inflammatory process resulting in clinical attachment loss (CAL), pocket depth (PD), and resulting in the loss of alveolar bone. Diagnostic imaging provides an adjunctive guidelines to assess the alveolar bone height in addition to clinical parameters such as PD and CAL. Aims and Objectives: The objectives of the study are to determine whether the digital intraoral periapical (IOPA) radiographs can be reliably used as an alternative to cone-beam computed tomography (CBCT) in the diagnosis of intrabony defects. Materials and Methods: A total of 25 patients with the presence of intrabony defects were included in the study. All the radiographic parameters were recorded using digital IOPA and CBCT. Various intrabony defect morphological characteristics such as height, depth, width, and angle were measured and compared between digital IOPA and CBCT. Statistics: The data was subjected to statistical analysis. Mann–Whitney U-test was performed for interexaminer comparison and independent t-test for intergroup comparison. Results: The mean intergroup comparison values between digital IOPA and CBCT in relation to defect width were 3.22 ± 1.10 and 3.20 ± 1.16, respectively (P = 0.970), in relation to defect depth were 7.71 ± 2.3 and 7.91 ± 2.4, respectively (P = 0.769), in relation to defect height were 3.80 ± 1.20 and 3.90 ± 1.2, respectively (P = 0.794), and in relation to defect angle were 34.82 ± 8.4 and 35.28 ± 0.8.6, respectively (P = 0.851). Conclusion: With the drawbacks of such as high radiation exposure, unavailability, and high financial cost, digital IOPA with digital software can be used as an alternative to CBCT for measuring intrabony defect morphological characteristics in periodontitis patients.
format article
author Chaitanya Adurty
Kanikanti Siva Tejaswi
Cheruvu Ramya Naga Shivani
Didla Navya
Cheni Gopinath
Ravindranath Dhulipalla
author_facet Chaitanya Adurty
Kanikanti Siva Tejaswi
Cheruvu Ramya Naga Shivani
Didla Navya
Cheni Gopinath
Ravindranath Dhulipalla
author_sort Chaitanya Adurty
title Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
title_short Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
title_full Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
title_fullStr Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
title_full_unstemmed Accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: A comparative study
title_sort accuracy of digital intraoral periapical radiography and cone-beam computed tomography in the measurement of intrabony defects: a comparative study
publisher Wolters Kluwer Medknow Publications
publishDate 2021
url https://doaj.org/article/c388273517b944ac96bb2873f153f927
work_keys_str_mv AT chaitanyaadurty accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
AT kanikantisivatejaswi accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
AT cheruvuramyanagashivani accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
AT didlanavya accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
AT chenigopinath accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
AT ravindranathdhulipalla accuracyofdigitalintraoralperiapicalradiographyandconebeamcomputedtomographyinthemeasurementofintrabonydefectsacomparativestudy
_version_ 1718431016003043328