Measurement of the dependence of ultra diluted gas transmittance on the size of the detector

Abstract We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200  $$\upmu$$ μ m. A Tunable Diode Las...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Jakub M. Ratajczak
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/c398ba5097e440249c763d07b46bcdd2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c398ba5097e440249c763d07b46bcdd2
record_format dspace
spelling oai:doaj.org-article:c398ba5097e440249c763d07b46bcdd22021-12-02T16:31:14ZMeasurement of the dependence of ultra diluted gas transmittance on the size of the detector10.1038/s41598-021-85568-w2045-2322https://doaj.org/article/c398ba5097e440249c763d07b46bcdd22021-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-85568-whttps://doaj.org/toc/2045-2322Abstract We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200  $$\upmu$$ μ m. A Tunable Diode Laser Absorption Spectroscopy type system was used. Transmittance of $$\sim$$ ∼  10 $$^{-2}$$ - 2  mbar water vapor on NIR absorption line $$\lambda =1368.60$$ λ = 1368.60  nm was measured using a 61.6 m long multi-pass cell placed inside the $$\sim$$ ∼  300 l vacuum chamber. The result of the experiment shows higher transmittances when the measurement is performed using smaller detectors. The difference reaches as much as $$1.23 \pm 0.1$$ 1.23 ± 0.1 %, which is greater than 0 with $$>5 \sigma$$ > 5 σ statistical significance. Qualitatively it is in agreement with the recently developed model of thin gas optical transmittance taking into account the quantum mechanical effects of spreading of the wave functions of individual gas particles.Jakub M. RatajczakNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-16 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Jakub M. Ratajczak
Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
description Abstract We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200  $$\upmu$$ μ m. A Tunable Diode Laser Absorption Spectroscopy type system was used. Transmittance of $$\sim$$ ∼  10 $$^{-2}$$ - 2  mbar water vapor on NIR absorption line $$\lambda =1368.60$$ λ = 1368.60  nm was measured using a 61.6 m long multi-pass cell placed inside the $$\sim$$ ∼  300 l vacuum chamber. The result of the experiment shows higher transmittances when the measurement is performed using smaller detectors. The difference reaches as much as $$1.23 \pm 0.1$$ 1.23 ± 0.1 %, which is greater than 0 with $$>5 \sigma$$ > 5 σ statistical significance. Qualitatively it is in agreement with the recently developed model of thin gas optical transmittance taking into account the quantum mechanical effects of spreading of the wave functions of individual gas particles.
format article
author Jakub M. Ratajczak
author_facet Jakub M. Ratajczak
author_sort Jakub M. Ratajczak
title Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_short Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_full Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_fullStr Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_full_unstemmed Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_sort measurement of the dependence of ultra diluted gas transmittance on the size of the detector
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/c398ba5097e440249c763d07b46bcdd2
work_keys_str_mv AT jakubmratajczak measurementofthedependenceofultradilutedgastransmittanceonthesizeofthedetector
_version_ 1718383898277183488