Conduction Abnormalities After Transcatheter Aortic Valve Replacement

Transcatheter aortic valve replacement (TAVR) has been established as a therapeutic option for patients with severe symptomatic aortic stenosis who are of intermediate or higher surgical risk. Several periprocedural complications are reduced with newer transcatheter heart valve generations; however,...

Full description

Saved in:
Bibliographic Details
Main Authors: Somsupha Kanjanauthai, Kabir Bhasin, Luigi Pirelli, Chad A Kliger
Format: article
Language:EN
Published: Radcliffe Medical Media 2019
Subjects:
Online Access:https://doaj.org/article/c4ad00e2062e4bf6ab807ce220bfecaa
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Transcatheter aortic valve replacement (TAVR) has been established as a therapeutic option for patients with severe symptomatic aortic stenosis who are of intermediate or higher surgical risk. Several periprocedural complications are reduced with newer transcatheter heart valve generations; however, conduction abnormalities and the need for permanent pacemaker implantation have remained unchanged and are the most frequent TAVR complications. The close relationship of the atrioventricular node and left bundle branch to the subaortic region explains these potential conduction abnormalities. This article highlights conduction abnormalities after TAVR with a focus on basic conduction system anatomy in relation to the aortic valve, the mechanism, incidence, predisposing factors for occurrence, impact on mortality and finally, proposed treatment algorithms for management.