In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning

Background: Dental scanners play a critical role in computer-aided design/computer-aided manufacturing technology. This study aimed to compare the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning.Materials and Methods: In this in-vitro experimental study, a typod...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Fariborz Vafaee, Mahsa Mohajeri, Naser Mohammad Gholi Mezerji, Marouf Ebrahim Zadeh
Formato: article
Lenguaje:EN
Publicado: Wolters Kluwer Medknow Publications 2021
Materias:
Acceso en línea:https://doaj.org/article/c5544073a8224436984ad4b0af1d6fae
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c5544073a8224436984ad4b0af1d6fae
record_format dspace
spelling oai:doaj.org-article:c5544073a8224436984ad4b0af1d6fae2021-11-12T10:10:18ZIn vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning1735-33272008-025510.4103/1735-3327.328752https://doaj.org/article/c5544073a8224436984ad4b0af1d6fae2021-01-01T00:00:00Zhttp://www.drjjournal.net/article.asp?issn=1735-3327;year=2021;volume=18;issue=1;spage=84;epage=84;aulast=Vafaeehttps://doaj.org/toc/1735-3327https://doaj.org/toc/2008-0255Background: Dental scanners play a critical role in computer-aided design/computer-aided manufacturing technology. This study aimed to compare the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning.Materials and Methods: In this in-vitro experimental study, a typodont model with a missing maxillary right first molar was prepared for a 3-unit fixed partial denture. Each scanner (Sirona inEos inLab, Sirona X5, Dentium, Imes icore 350I I3D, Amann Girrbach map 100, 3Shape D100, 3Shape E3) performed seven scans of the typodont, and the data were analyzed using 3D-Tool software. The abutment length, abutment width, arch length, and interdental distance were measured. To assess the accuracy of each scanner, trueness was evaluated by superimposing the scanned data on true values obtained by the 3shape Triosscanner as the reference. Precision was evaluated by superimposing a pair of data sets obtained from the same scanner. Precision and trueness of the scanners were compared using the one-way ANOVA followed by the post-hoc Tukey's HSD test and one-sample t-test (P<0.05 was considerer significant).Results: The precision of scanners ranged from 14 μm (3Shape Trios) to 45 μm (Imes icore 350i), whereas the trueness ranged from 38 μm (3Shape d700) to 71 μm (Sirona X5).Conclusion: The reported trueness values for 3Shape Trios, Sirona inEos inLab, Sirona x5, Dentium, Imes icore350i, Amann Girrbach, 3Shape d700, and 3Shape e3 were 63, 45, 71, 67, 70, 53, 38, and 42 μm, respectively, whereas the precision values were 14, 29, 44, 34, 45, 44, 30 and 28 μm, respectively.Fariborz VafaeeMahsa MohajeriNaser Mohammad Gholi MezerjiMarouf Ebrahim ZadehWolters Kluwer Medknow Publicationsarticleaccuracydental scannerprecisiontruenessDentistryRK1-715ENDental Research Journal, Vol 18, Iss 1, Pp 84-84 (2021)
institution DOAJ
collection DOAJ
language EN
topic accuracy
dental scanner
precision
trueness
Dentistry
RK1-715
spellingShingle accuracy
dental scanner
precision
trueness
Dentistry
RK1-715
Fariborz Vafaee
Mahsa Mohajeri
Naser Mohammad Gholi Mezerji
Marouf Ebrahim Zadeh
In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
description Background: Dental scanners play a critical role in computer-aided design/computer-aided manufacturing technology. This study aimed to compare the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning.Materials and Methods: In this in-vitro experimental study, a typodont model with a missing maxillary right first molar was prepared for a 3-unit fixed partial denture. Each scanner (Sirona inEos inLab, Sirona X5, Dentium, Imes icore 350I I3D, Amann Girrbach map 100, 3Shape D100, 3Shape E3) performed seven scans of the typodont, and the data were analyzed using 3D-Tool software. The abutment length, abutment width, arch length, and interdental distance were measured. To assess the accuracy of each scanner, trueness was evaluated by superimposing the scanned data on true values obtained by the 3shape Triosscanner as the reference. Precision was evaluated by superimposing a pair of data sets obtained from the same scanner. Precision and trueness of the scanners were compared using the one-way ANOVA followed by the post-hoc Tukey's HSD test and one-sample t-test (P<0.05 was considerer significant).Results: The precision of scanners ranged from 14 μm (3Shape Trios) to 45 μm (Imes icore 350i), whereas the trueness ranged from 38 μm (3Shape d700) to 71 μm (Sirona X5).Conclusion: The reported trueness values for 3Shape Trios, Sirona inEos inLab, Sirona x5, Dentium, Imes icore350i, Amann Girrbach, 3Shape d700, and 3Shape e3 were 63, 45, 71, 67, 70, 53, 38, and 42 μm, respectively, whereas the precision values were 14, 29, 44, 34, 45, 44, 30 and 28 μm, respectively.
format article
author Fariborz Vafaee
Mahsa Mohajeri
Naser Mohammad Gholi Mezerji
Marouf Ebrahim Zadeh
author_facet Fariborz Vafaee
Mahsa Mohajeri
Naser Mohammad Gholi Mezerji
Marouf Ebrahim Zadeh
author_sort Fariborz Vafaee
title In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
title_short In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
title_full In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
title_fullStr In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
title_full_unstemmed In vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
title_sort in vitro comparison of the accuracy (precision and trueness) of eight dental scanners for dental bridge scanning
publisher Wolters Kluwer Medknow Publications
publishDate 2021
url https://doaj.org/article/c5544073a8224436984ad4b0af1d6fae
work_keys_str_mv AT fariborzvafaee invitrocomparisonoftheaccuracyprecisionandtruenessofeightdentalscannersfordentalbridgescanning
AT mahsamohajeri invitrocomparisonoftheaccuracyprecisionandtruenessofeightdentalscannersfordentalbridgescanning
AT nasermohammadgholimezerji invitrocomparisonoftheaccuracyprecisionandtruenessofeightdentalscannersfordentalbridgescanning
AT maroufebrahimzadeh invitrocomparisonoftheaccuracyprecisionandtruenessofeightdentalscannersfordentalbridgescanning
_version_ 1718431016626946048