Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment

Jianhua Wang,1 Lele Cui,1 Meixiao Shen,1 Victor L Perez,1 Michael R Wang21Bascom Palmer Eye Institute, University of Miami Leonard M Miller School of Medicine, 2Electrical and Computer Engineering, University of Miami, Miami, FL, USAPurpose: This study was designed to determine the ability of ultra-...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wang J, Cui L, Shen M, Perez VL, Wang MR
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://doaj.org/article/c5a667adf7ee44f6b3c287f6e5556565
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c5a667adf7ee44f6b3c287f6e5556565
record_format dspace
spelling oai:doaj.org-article:c5a667adf7ee44f6b3c287f6e55565652021-12-02T06:17:23ZUltra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment1177-54671177-5483https://doaj.org/article/c5a667adf7ee44f6b3c287f6e55565652012-06-01T00:00:00Zhttp://www.dovepress.com/ultra-high-resolution-optical-coherence-tomography-for-monitoring-tear-a10168https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Jianhua Wang,1 Lele Cui,1 Meixiao Shen,1 Victor L Perez,1 Michael R Wang21Bascom Palmer Eye Institute, University of Miami Leonard M Miller School of Medicine, 2Electrical and Computer Engineering, University of Miami, Miami, FL, USAPurpose: This study was designed to determine the ability of ultra-high-resolution optical coherence tomography (UHR-OCT) to monitor tear meniscus volume after dry eye treatment with Restasis® (0.05% cyclosporine).Methods: UHR-OCT was used to image the upper and lower tear menisci (height and volume) in 14 consecutive dry eye patients at baseline. The treatment group was initiated on daily Restasis and measurements were repeated at 1 and 2 months while on treatment. All measurements were performed immediately after a blink.Results: The baseline tear meniscus volumes were 0.40 ± 0.19 µL (upper) and 0.43 ± 0.18 µL (lower). In the treatment group, tear meniscus heights showed significant increases of both upper (post-hoc test with Bonferroni correction: P = 0.003) and lower (P = 0.0003) tear menisci, after 1 month on Restasis. The tear meniscus volumes in the treatment group after 1 month of Restasis showed significant increases of both upper (P = 0.007) and lower (P = 0.007) tear menisci. At 2 months, the increase of the tear meniscus was still evident in all measured variables compared with baseline (P < 0.05).Conclusion: UHR-OCT offers a promising tool for monitoring dry eye treatment. With this method, a measurable increase in tear meniscus volume was evident after 1 month of treatment with Restasis in dry eye patients.Keywords: tear menisci, UHR-OCT, tear dynamics, dry eye, Restasis®Wang JCui LShen MPerez VLWang MRDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 933-938 (2012)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Wang J
Cui L
Shen M
Perez VL
Wang MR
Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
description Jianhua Wang,1 Lele Cui,1 Meixiao Shen,1 Victor L Perez,1 Michael R Wang21Bascom Palmer Eye Institute, University of Miami Leonard M Miller School of Medicine, 2Electrical and Computer Engineering, University of Miami, Miami, FL, USAPurpose: This study was designed to determine the ability of ultra-high-resolution optical coherence tomography (UHR-OCT) to monitor tear meniscus volume after dry eye treatment with Restasis® (0.05% cyclosporine).Methods: UHR-OCT was used to image the upper and lower tear menisci (height and volume) in 14 consecutive dry eye patients at baseline. The treatment group was initiated on daily Restasis and measurements were repeated at 1 and 2 months while on treatment. All measurements were performed immediately after a blink.Results: The baseline tear meniscus volumes were 0.40 ± 0.19 µL (upper) and 0.43 ± 0.18 µL (lower). In the treatment group, tear meniscus heights showed significant increases of both upper (post-hoc test with Bonferroni correction: P = 0.003) and lower (P = 0.0003) tear menisci, after 1 month on Restasis. The tear meniscus volumes in the treatment group after 1 month of Restasis showed significant increases of both upper (P = 0.007) and lower (P = 0.007) tear menisci. At 2 months, the increase of the tear meniscus was still evident in all measured variables compared with baseline (P < 0.05).Conclusion: UHR-OCT offers a promising tool for monitoring dry eye treatment. With this method, a measurable increase in tear meniscus volume was evident after 1 month of treatment with Restasis in dry eye patients.Keywords: tear menisci, UHR-OCT, tear dynamics, dry eye, Restasis®
format article
author Wang J
Cui L
Shen M
Perez VL
Wang MR
author_facet Wang J
Cui L
Shen M
Perez VL
Wang MR
author_sort Wang J
title Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
title_short Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
title_full Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
title_fullStr Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
title_full_unstemmed Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
title_sort ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
publisher Dove Medical Press
publishDate 2012
url https://doaj.org/article/c5a667adf7ee44f6b3c287f6e5556565
work_keys_str_mv AT wangj ultrahighresolutionopticalcoherencetomographyformonitoringtearmeniscusvolumeindryeyeaftertopicalcyclosporinetreatment
AT cuil ultrahighresolutionopticalcoherencetomographyformonitoringtearmeniscusvolumeindryeyeaftertopicalcyclosporinetreatment
AT shenm ultrahighresolutionopticalcoherencetomographyformonitoringtearmeniscusvolumeindryeyeaftertopicalcyclosporinetreatment
AT perezvl ultrahighresolutionopticalcoherencetomographyformonitoringtearmeniscusvolumeindryeyeaftertopicalcyclosporinetreatment
AT wangmr ultrahighresolutionopticalcoherencetomographyformonitoringtearmeniscusvolumeindryeyeaftertopicalcyclosporinetreatment
_version_ 1718400015810953216