External assessment of the EUROMACS right-sided heart failure risk score

Abstract The EUROMACS Right-Sided Heart Failure Risk Score was developed to predict right ventricular failure (RVF) after left ventricular assist device (LVAD) placement. The predictive ability of the EUROMACS score has not been tested in other cohorts. We performed a single center analysis of a con...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hirak Shah, Thomas Murray, Jessica Schultz, Ranjit John, Cindy M. Martin, Thenappan Thenappan, Rebecca Cogswell
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/c5e3130bb105412d9d89b67d2e5ab1c4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c5e3130bb105412d9d89b67d2e5ab1c4
record_format dspace
spelling oai:doaj.org-article:c5e3130bb105412d9d89b67d2e5ab1c42021-12-02T15:08:10ZExternal assessment of the EUROMACS right-sided heart failure risk score10.1038/s41598-021-94792-32045-2322https://doaj.org/article/c5e3130bb105412d9d89b67d2e5ab1c42021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-94792-3https://doaj.org/toc/2045-2322Abstract The EUROMACS Right-Sided Heart Failure Risk Score was developed to predict right ventricular failure (RVF) after left ventricular assist device (LVAD) placement. The predictive ability of the EUROMACS score has not been tested in other cohorts. We performed a single center analysis of a continuous-flow (CF) LVAD cohort (n = 254) where we calculated EUROMACS risk scores and assessed for right ventricular heart failure after LVAD implantation. Thirty-nine percent of patients (100/254) had post-operative RVF, of which 9% (23/254) required prolonged inotropic support and 5% (12/254) required RVAD placement. For patients who developed RVF after LVAD implantation, there was a 45% increase in the hazards of death on LVAD support (HR 1.45, 95% CI 0.98–2.2, p = 0.066). Two variables in the EUROMACS score (Hemoglobin and Right Atrial Pressure to Pulmonary Capillary Wedge Pressure ratio) were not predictive of RVF in our cohort. Overall, the EUROMACS score had poor external discrimination in our cohort with area under the curve of 58% (95% CI 52–66%). Further work is necessary to enhance our ability to predict RVF after LVAD implantation.Hirak ShahThomas MurrayJessica SchultzRanjit JohnCindy M. MartinThenappan ThenappanRebecca CogswellNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Hirak Shah
Thomas Murray
Jessica Schultz
Ranjit John
Cindy M. Martin
Thenappan Thenappan
Rebecca Cogswell
External assessment of the EUROMACS right-sided heart failure risk score
description Abstract The EUROMACS Right-Sided Heart Failure Risk Score was developed to predict right ventricular failure (RVF) after left ventricular assist device (LVAD) placement. The predictive ability of the EUROMACS score has not been tested in other cohorts. We performed a single center analysis of a continuous-flow (CF) LVAD cohort (n = 254) where we calculated EUROMACS risk scores and assessed for right ventricular heart failure after LVAD implantation. Thirty-nine percent of patients (100/254) had post-operative RVF, of which 9% (23/254) required prolonged inotropic support and 5% (12/254) required RVAD placement. For patients who developed RVF after LVAD implantation, there was a 45% increase in the hazards of death on LVAD support (HR 1.45, 95% CI 0.98–2.2, p = 0.066). Two variables in the EUROMACS score (Hemoglobin and Right Atrial Pressure to Pulmonary Capillary Wedge Pressure ratio) were not predictive of RVF in our cohort. Overall, the EUROMACS score had poor external discrimination in our cohort with area under the curve of 58% (95% CI 52–66%). Further work is necessary to enhance our ability to predict RVF after LVAD implantation.
format article
author Hirak Shah
Thomas Murray
Jessica Schultz
Ranjit John
Cindy M. Martin
Thenappan Thenappan
Rebecca Cogswell
author_facet Hirak Shah
Thomas Murray
Jessica Schultz
Ranjit John
Cindy M. Martin
Thenappan Thenappan
Rebecca Cogswell
author_sort Hirak Shah
title External assessment of the EUROMACS right-sided heart failure risk score
title_short External assessment of the EUROMACS right-sided heart failure risk score
title_full External assessment of the EUROMACS right-sided heart failure risk score
title_fullStr External assessment of the EUROMACS right-sided heart failure risk score
title_full_unstemmed External assessment of the EUROMACS right-sided heart failure risk score
title_sort external assessment of the euromacs right-sided heart failure risk score
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/c5e3130bb105412d9d89b67d2e5ab1c4
work_keys_str_mv AT hirakshah externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT thomasmurray externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT jessicaschultz externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT ranjitjohn externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT cindymmartin externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT thenappanthenappan externalassessmentoftheeuromacsrightsidedheartfailureriskscore
AT rebeccacogswell externalassessmentoftheeuromacsrightsidedheartfailureriskscore
_version_ 1718388279947034624