Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection.
Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/c69f06cc17c146eb92f1f07d996af3ab |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:c69f06cc17c146eb92f1f07d996af3ab |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:c69f06cc17c146eb92f1f07d996af3ab2021-11-18T09:02:11ZPlasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection.1932-620310.1371/journal.pone.0070374https://doaj.org/article/c69f06cc17c146eb92f1f07d996af3ab2013-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/23922985/pdf/?tool=EBIhttps://doaj.org/toc/1932-6203Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%).Salvatore SotgiaElisabetta PisanuGianfranco PintusGian Luca ErreGerard Aime PinnaLuca DeianaCiriaco CarruAngelo ZinelluPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 8, Iss 7, p e70374 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Salvatore Sotgia Elisabetta Pisanu Gianfranco Pintus Gian Luca Erre Gerard Aime Pinna Luca Deiana Ciriaco Carru Angelo Zinellu Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
description |
Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%). |
format |
article |
author |
Salvatore Sotgia Elisabetta Pisanu Gianfranco Pintus Gian Luca Erre Gerard Aime Pinna Luca Deiana Ciriaco Carru Angelo Zinellu |
author_facet |
Salvatore Sotgia Elisabetta Pisanu Gianfranco Pintus Gian Luca Erre Gerard Aime Pinna Luca Deiana Ciriaco Carru Angelo Zinellu |
author_sort |
Salvatore Sotgia |
title |
Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
title_short |
Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
title_full |
Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
title_fullStr |
Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
title_full_unstemmed |
Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection. |
title_sort |
plasma l-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-iaf) and fluorescence detection. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2013 |
url |
https://doaj.org/article/c69f06cc17c146eb92f1f07d996af3ab |
work_keys_str_mv |
AT salvatoresotgia plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT elisabettapisanu plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT gianfrancopintus plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT gianlucaerre plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT gerardaimepinna plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT lucadeiana plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT ciriacocarru plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection AT angelozinellu plasmalergothioneinemeasurementbyhighperformanceliquidchromatographyandcapillaryelectrophoresisafteraprecolumnderivatizationwith5iodoacetamidofluorescein5iafandfluorescencedetection |
_version_ |
1718421048541577216 |