An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER
The large-caliber steady-state magnetic-field testing system is an important device for the International Thermonuclear Experimental Reactor, which is mainly used for electromagnetic compatibility tests in a strong magnetic field environment. The uniform magnetic field area needs to be measured to e...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
AIP Publishing LLC
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/c79f3f0216e34a51b607b04cfc0af5fc |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:c79f3f0216e34a51b607b04cfc0af5fc |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:c79f3f0216e34a51b607b04cfc0af5fc2021-12-01T18:52:06ZAn improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER2158-322610.1063/5.0066136https://doaj.org/article/c79f3f0216e34a51b607b04cfc0af5fc2021-11-01T00:00:00Zhttp://dx.doi.org/10.1063/5.0066136https://doaj.org/toc/2158-3226The large-caliber steady-state magnetic-field testing system is an important device for the International Thermonuclear Experimental Reactor, which is mainly used for electromagnetic compatibility tests in a strong magnetic field environment. The uniform magnetic field area needs to be measured to ensure the correctness of the design after the completion of the platform. This paper mainly analyzes the relationship between the magnetic field probe and error, studies the detection effect of different arrangement methods of magnetic field probe points, and obtains a more accurate probe arrangement method through comparative analysis. Then, the principle and structure of the acquisition and detection system are studied, and the multipoint synchronous Hall array magnetic field detection system of the magnetic field is built by using the Hall probe to realize the omnidirectional measurement of the magnetic field. Finally, the Hall probe is calibrated and tested by experiments, and a test platform is built to test the magnetic field. The results verify the correctness of the analysis.Ya HuangLi JiangHong LeiGe GaoXi DengPeng WuJie ZhangAIP Publishing LLCarticlePhysicsQC1-999ENAIP Advances, Vol 11, Iss 11, Pp 115125-115125-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Physics QC1-999 |
spellingShingle |
Physics QC1-999 Ya Huang Li Jiang Hong Lei Ge Gao Xi Deng Peng Wu Jie Zhang An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
description |
The large-caliber steady-state magnetic-field testing system is an important device for the International Thermonuclear Experimental Reactor, which is mainly used for electromagnetic compatibility tests in a strong magnetic field environment. The uniform magnetic field area needs to be measured to ensure the correctness of the design after the completion of the platform. This paper mainly analyzes the relationship between the magnetic field probe and error, studies the detection effect of different arrangement methods of magnetic field probe points, and obtains a more accurate probe arrangement method through comparative analysis. Then, the principle and structure of the acquisition and detection system are studied, and the multipoint synchronous Hall array magnetic field detection system of the magnetic field is built by using the Hall probe to realize the omnidirectional measurement of the magnetic field. Finally, the Hall probe is calibrated and tested by experiments, and a test platform is built to test the magnetic field. The results verify the correctness of the analysis. |
format |
article |
author |
Ya Huang Li Jiang Hong Lei Ge Gao Xi Deng Peng Wu Jie Zhang |
author_facet |
Ya Huang Li Jiang Hong Lei Ge Gao Xi Deng Peng Wu Jie Zhang |
author_sort |
Ya Huang |
title |
An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
title_short |
An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
title_full |
An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
title_fullStr |
An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
title_full_unstemmed |
An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER |
title_sort |
improved measurement scheme of the large-caliber steady-state magnetic-field testing system for iter |
publisher |
AIP Publishing LLC |
publishDate |
2021 |
url |
https://doaj.org/article/c79f3f0216e34a51b607b04cfc0af5fc |
work_keys_str_mv |
AT yahuang animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT lijiang animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT honglei animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT gegao animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT xideng animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT pengwu animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT jiezhang animprovedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT yahuang improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT lijiang improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT honglei improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT gegao improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT xideng improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT pengwu improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter AT jiezhang improvedmeasurementschemeofthelargecalibersteadystatemagneticfieldtestingsystemforiter |
_version_ |
1718404654286503936 |