New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system

Tomoyuki Chihara,1 Mihori Kita21Department of Ophthalmology, Hyogo Prefectural Amagasaki Hospital, Hyogo, 2Department of Ophthalmology, National Hospital Organization Kyoto Medical Center, Kyoto, JapanAbstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chihara T, Kita M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/c822a62ffda640a79288cadd5f399266
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c822a62ffda640a79288cadd5f399266
record_format dspace
spelling oai:doaj.org-article:c822a62ffda640a79288cadd5f3992662021-12-02T01:45:53ZNew type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system1177-54671177-5483https://doaj.org/article/c822a62ffda640a79288cadd5f3992662013-02-01T00:00:00Zhttp://www.dovepress.com/new-type-of-antidrying-lens-for-vitreous-surgery-with-a-noncontact-wid-a12225https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Tomoyuki Chihara,1 Mihori Kita21Department of Ophthalmology, Hyogo Prefectural Amagasaki Hospital, Hyogo, 2Department of Ophthalmology, National Hospital Organization Kyoto Medical Center, Kyoto, JapanAbstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the more serious problems when using a noncontact type wide-angle viewing system. We developed an antidrying corneal contact lens for use with this type of viewing system. The lens has a very thin meniscus made of polymethyl methacrylate with a large outer diameter. Following application of the viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of our lens contributed to its overall stability. The smooth surface of this prototype lens was able to achieve an intraoperative view of good quality, not only by preventing the cornea from drying, but also by providing a smooth surface over the entire cornea.Keywords: vitrectomy, wide-angle viewing system, contact lensChihara TKita MDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 353-355 (2013)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Chihara T
Kita M
New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
description Tomoyuki Chihara,1 Mihori Kita21Department of Ophthalmology, Hyogo Prefectural Amagasaki Hospital, Hyogo, 2Department of Ophthalmology, National Hospital Organization Kyoto Medical Center, Kyoto, JapanAbstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the more serious problems when using a noncontact type wide-angle viewing system. We developed an antidrying corneal contact lens for use with this type of viewing system. The lens has a very thin meniscus made of polymethyl methacrylate with a large outer diameter. Following application of the viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of our lens contributed to its overall stability. The smooth surface of this prototype lens was able to achieve an intraoperative view of good quality, not only by preventing the cornea from drying, but also by providing a smooth surface over the entire cornea.Keywords: vitrectomy, wide-angle viewing system, contact lens
format article
author Chihara T
Kita M
author_facet Chihara T
Kita M
author_sort Chihara T
title New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
title_short New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
title_full New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
title_fullStr New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
title_full_unstemmed New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
title_sort new type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/c822a62ffda640a79288cadd5f399266
work_keys_str_mv AT chiharat newtypeofantidryinglensforvitreoussurgerywithanoncontactwideangleviewingsystem
AT kitam newtypeofantidryinglensforvitreoussurgerywithanoncontactwideangleviewingsystem
_version_ 1718402922673340416