Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/c8270cdf443f4b14916068ad253faa38 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:c8270cdf443f4b14916068ad253faa38 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:c8270cdf443f4b14916068ad253faa382021-11-18T07:46:11ZDosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.1932-620310.1371/journal.pone.0063418https://doaj.org/article/c8270cdf443f4b14916068ad253faa382013-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/23671677/pdf/?tool=EBIhttps://doaj.org/toc/1932-6203This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in (60)Co gamma-ray and 6 MV x-ray reference (10×10 cm(2)) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields smaller than 10 mm diameters.Guerda Massillon-J LDiego Cueva-PrócelPorfirio Díaz-AguirreMiguel Rodríguez-PonceFlor Herrera-MartínezPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 8, Iss 5, p e63418 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Guerda Massillon-J L Diego Cueva-Prócel Porfirio Díaz-Aguirre Miguel Rodríguez-Ponce Flor Herrera-Martínez Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
description |
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in (60)Co gamma-ray and 6 MV x-ray reference (10×10 cm(2)) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields smaller than 10 mm diameters. |
format |
article |
author |
Guerda Massillon-J L Diego Cueva-Prócel Porfirio Díaz-Aguirre Miguel Rodríguez-Ponce Flor Herrera-Martínez |
author_facet |
Guerda Massillon-J L Diego Cueva-Prócel Porfirio Díaz-Aguirre Miguel Rodríguez-Ponce Flor Herrera-Martínez |
author_sort |
Guerda Massillon-J L |
title |
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
title_short |
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
title_full |
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
title_fullStr |
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
title_full_unstemmed |
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. |
title_sort |
dosimetry for small fields in stereotactic radiosurgery using gafchromic md-v2-55 film, tld-100 and alanine dosimeters. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2013 |
url |
https://doaj.org/article/c8270cdf443f4b14916068ad253faa38 |
work_keys_str_mv |
AT guerdamassillonjl dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters AT diegocuevaprocel dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters AT porfiriodiazaguirre dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters AT miguelrodriguezponce dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters AT florherreramartinez dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters |
_version_ |
1718423000814977024 |