Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries

Hisato Ohno Ohno Eye Clinic, Asaka, Saitama, JapanCorrespondence: Hisato OhnoOhno Eye Clinic, 2-14-18 Nishihara, Asaka, Saitama 351-0034, JapanTel +81 48 424 3733Fax +81 48 424 5571Email vitrectman@ohno-eye.comPurpose: This study aimed to assess the utility of the three-dimensional (3D) heads-up vis...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Ohno H
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/c85a87da16e24c33be0cae9e1fab47d1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c85a87da16e24c33be0cae9e1fab47d1
record_format dspace
spelling oai:doaj.org-article:c85a87da16e24c33be0cae9e1fab47d12021-12-02T08:47:56ZUtility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries1177-5483https://doaj.org/article/c85a87da16e24c33be0cae9e1fab47d12019-10-01T00:00:00Zhttps://www.dovepress.com/utility-of-three-dimensional-heads-up-surgery-in-cataract-and-minimall-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Hisato Ohno Ohno Eye Clinic, Asaka, Saitama, JapanCorrespondence: Hisato OhnoOhno Eye Clinic, 2-14-18 Nishihara, Asaka, Saitama 351-0034, JapanTel +81 48 424 3733Fax +81 48 424 5571Email vitrectman@ohno-eye.comPurpose: This study aimed to assess the utility of the three-dimensional (3D) heads-up visualization system for minimal incision cataract surgery (MICS) and minimally invasive glaucoma surgeries (MIGSs).Methods: Toric intraocular lens (IOL) implantation with phacoemulsification and trabecular microbypass stent implantation in patients with cataract and open-angle glaucoma were performed using the heads-up 3D visualization system combined with surgical navigation rather than the conventional microscope.Results: This procedure was found to have the following advantages: the ability to clearly observe the anterior chamber angle image without requiring frequent focus adjustment owing to the extended depth of field and emphasized stereoscopic effect provided by this system and maintain the surgeon’s posture.Conclusion: The feasibility and comfort of this system are greater than those of the conventional microscopic for performing MICS and MIGS.Keywords: toric intraocular lens, phacoemulsification, open-angle glaucomaOhno HDove Medical Pressarticletoric intraocular lensphacoemulsificationopen angle glaucomaOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 2071-2073 (2019)
institution DOAJ
collection DOAJ
language EN
topic toric intraocular lens
phacoemulsification
open angle glaucoma
Ophthalmology
RE1-994
spellingShingle toric intraocular lens
phacoemulsification
open angle glaucoma
Ophthalmology
RE1-994
Ohno H
Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
description Hisato Ohno Ohno Eye Clinic, Asaka, Saitama, JapanCorrespondence: Hisato OhnoOhno Eye Clinic, 2-14-18 Nishihara, Asaka, Saitama 351-0034, JapanTel +81 48 424 3733Fax +81 48 424 5571Email vitrectman@ohno-eye.comPurpose: This study aimed to assess the utility of the three-dimensional (3D) heads-up visualization system for minimal incision cataract surgery (MICS) and minimally invasive glaucoma surgeries (MIGSs).Methods: Toric intraocular lens (IOL) implantation with phacoemulsification and trabecular microbypass stent implantation in patients with cataract and open-angle glaucoma were performed using the heads-up 3D visualization system combined with surgical navigation rather than the conventional microscope.Results: This procedure was found to have the following advantages: the ability to clearly observe the anterior chamber angle image without requiring frequent focus adjustment owing to the extended depth of field and emphasized stereoscopic effect provided by this system and maintain the surgeon’s posture.Conclusion: The feasibility and comfort of this system are greater than those of the conventional microscopic for performing MICS and MIGS.Keywords: toric intraocular lens, phacoemulsification, open-angle glaucoma
format article
author Ohno H
author_facet Ohno H
author_sort Ohno H
title Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
title_short Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
title_full Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
title_fullStr Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
title_full_unstemmed Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries
title_sort utility of three-dimensional heads-up surgery in cataract and minimally invasive glaucoma surgeries
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/c85a87da16e24c33be0cae9e1fab47d1
work_keys_str_mv AT ohnoh utilityofthreedimensionalheadsupsurgeryincataractandminimallyinvasiveglaucomasurgeries
_version_ 1718398390478307328