Home-based visual field test for glaucoma screening comparison with Humphrey perimeter

Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Stylianos Kandarakis, Konstantinos Droutsas, Konstantinos Andreanos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a home-based visual field e...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tsapakis S, Papaconstantinou D, Diagourtas A, Kandarakis S, Droutsas K, Andreanos K, Brouzas D
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/c8fb172061f84b64b867971022372680
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c8fb172061f84b64b867971022372680
record_format dspace
spelling oai:doaj.org-article:c8fb172061f84b64b8679710223726802021-12-02T00:34:44ZHome-based visual field test for glaucoma screening comparison with Humphrey perimeter1177-5483https://doaj.org/article/c8fb172061f84b64b8679710223726802018-12-01T00:00:00Zhttps://www.dovepress.com/home-based-visual-field-test-for-glaucoma-screening-comparison-with-hu-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Stylianos Kandarakis, Konstantinos Droutsas, Konstantinos Andreanos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet.Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours.Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (P<0.001). Sensitivity ranged from 0.637 to 0.942, and specificity ranged from 0.735 to 0.497.Conclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening. Keywords: glaucoma, screening, internet, computer monitor, android smart-phone, online visual field, virtual reality, teleophthalmology, telemedicine Tsapakis SPapaconstantinou DDiagourtas AKandarakis SDroutsas KAndreanos KBrouzas DDove Medical PressarticleGlaucomaonline visual fieldvirtual realityteleophthalmologytelemedicineOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 2597-2606 (2018)
institution DOAJ
collection DOAJ
language EN
topic Glaucoma
online visual field
virtual reality
teleophthalmology
telemedicine
Ophthalmology
RE1-994
spellingShingle Glaucoma
online visual field
virtual reality
teleophthalmology
telemedicine
Ophthalmology
RE1-994
Tsapakis S
Papaconstantinou D
Diagourtas A
Kandarakis S
Droutsas K
Andreanos K
Brouzas D
Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
description Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Stylianos Kandarakis, Konstantinos Droutsas, Konstantinos Andreanos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet.Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours.Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (P<0.001). Sensitivity ranged from 0.637 to 0.942, and specificity ranged from 0.735 to 0.497.Conclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening. Keywords: glaucoma, screening, internet, computer monitor, android smart-phone, online visual field, virtual reality, teleophthalmology, telemedicine 
format article
author Tsapakis S
Papaconstantinou D
Diagourtas A
Kandarakis S
Droutsas K
Andreanos K
Brouzas D
author_facet Tsapakis S
Papaconstantinou D
Diagourtas A
Kandarakis S
Droutsas K
Andreanos K
Brouzas D
author_sort Tsapakis S
title Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
title_short Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
title_full Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
title_fullStr Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
title_full_unstemmed Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
title_sort home-based visual field test for glaucoma screening comparison with humphrey perimeter
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/c8fb172061f84b64b867971022372680
work_keys_str_mv AT tsapakiss homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT papaconstantinoud homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT diagourtasa homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT kandarakiss homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT droutsask homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT andreanosk homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
AT brouzasd homebasedvisualfieldtestforglaucomascreeningcomparisonwithhumphreyperimeter
_version_ 1718403646185537536