Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.

Covered self-expandable metal stents (CSEMS) are often used for palliative endoscopic biliary drainage; however, the unobstructed period is limited because of sludge occlusion. The present study aimed to evaluate the biosafety of a novel poly(2-methoxyethyl acrylate)-coated CSEMS (PMEA-CSEMS) for sl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tetsuya Ishizawa, Naohiko Makino, Yasuharu Kakizaki, Akiko Matsuda, Yoshihide Toyokawa, Shun Ooyama, Masaru Tanaka, Yoshiyuki Ueno
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/c9230a85289045588e1119057859c658
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c9230a85289045588e1119057859c658
record_format dspace
spelling oai:doaj.org-article:c9230a85289045588e1119057859c6582021-12-02T20:14:11ZBiosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.1932-620310.1371/journal.pone.0257828https://doaj.org/article/c9230a85289045588e1119057859c6582021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0257828https://doaj.org/toc/1932-6203Covered self-expandable metal stents (CSEMS) are often used for palliative endoscopic biliary drainage; however, the unobstructed period is limited because of sludge occlusion. The present study aimed to evaluate the biosafety of a novel poly(2-methoxyethyl acrylate)-coated CSEMS (PMEA-CSEMS) for sludge resistance and examine its biosafety in vivo. Using endoscopic retrograde cholangiopancreatography, we placed the PMEA-CSEMS into six normal porcine bile ducts and conventional CSEMS into three normal porcine bile ducts. We performed serological examination and undecalcified histological analysis at 1, 3, and 6 months during follow-up. In the bile ducts with PMEA-CSEMS or conventional CSEMS, we observed no increase in liver enzyme or inflammatory marker levels in the serological investigations and mild fibrosis but no inflammatory response in the histopathological analyses. Thus, we demonstrated the biosafety of PMEA-CSEMS in vivo.Tetsuya IshizawaNaohiko MakinoYasuharu KakizakiAkiko MatsudaYoshihide ToyokawaShun OoyamaMasaru TanakaYoshiyuki UenoPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 9, p e0257828 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Tetsuya Ishizawa
Naohiko Makino
Yasuharu Kakizaki
Akiko Matsuda
Yoshihide Toyokawa
Shun Ooyama
Masaru Tanaka
Yoshiyuki Ueno
Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
description Covered self-expandable metal stents (CSEMS) are often used for palliative endoscopic biliary drainage; however, the unobstructed period is limited because of sludge occlusion. The present study aimed to evaluate the biosafety of a novel poly(2-methoxyethyl acrylate)-coated CSEMS (PMEA-CSEMS) for sludge resistance and examine its biosafety in vivo. Using endoscopic retrograde cholangiopancreatography, we placed the PMEA-CSEMS into six normal porcine bile ducts and conventional CSEMS into three normal porcine bile ducts. We performed serological examination and undecalcified histological analysis at 1, 3, and 6 months during follow-up. In the bile ducts with PMEA-CSEMS or conventional CSEMS, we observed no increase in liver enzyme or inflammatory marker levels in the serological investigations and mild fibrosis but no inflammatory response in the histopathological analyses. Thus, we demonstrated the biosafety of PMEA-CSEMS in vivo.
format article
author Tetsuya Ishizawa
Naohiko Makino
Yasuharu Kakizaki
Akiko Matsuda
Yoshihide Toyokawa
Shun Ooyama
Masaru Tanaka
Yoshiyuki Ueno
author_facet Tetsuya Ishizawa
Naohiko Makino
Yasuharu Kakizaki
Akiko Matsuda
Yoshihide Toyokawa
Shun Ooyama
Masaru Tanaka
Yoshiyuki Ueno
author_sort Tetsuya Ishizawa
title Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
title_short Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
title_full Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
title_fullStr Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
title_full_unstemmed Biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
title_sort biosafety of a novel covered self-expandable metal stent coated with poly(2-methoxyethyl acrylate) in vivo.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/c9230a85289045588e1119057859c658
work_keys_str_mv AT tetsuyaishizawa biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT naohikomakino biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT yasuharukakizaki biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT akikomatsuda biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT yoshihidetoyokawa biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT shunooyama biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT masarutanaka biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
AT yoshiyukiueno biosafetyofanovelcoveredselfexpandablemetalstentcoatedwithpoly2methoxyethylacrylateinvivo
_version_ 1718374733275201536