Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats

Abstract Sepsis causes multiple organs failures and eventually death. Changes in blood constituents due to sepsis lead to alterations in hemorheological properties, and cell adhesiveness. In this study, a new microfluidic system is proposed to measure temporal variations in biophysical properties of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Eunseop Yeom, Hye Mi Kim, Jun Hong Park, Woorak Choi, Junsang Doh, Sang Joon Lee
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/c9dd265acec04bbe87094de954ec8e33
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c9dd265acec04bbe87094de954ec8e33
record_format dspace
spelling oai:doaj.org-article:c9dd265acec04bbe87094de954ec8e332021-12-02T12:30:12ZMicrofluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats10.1038/s41598-017-01985-w2045-2322https://doaj.org/article/c9dd265acec04bbe87094de954ec8e332017-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-01985-whttps://doaj.org/toc/2045-2322Abstract Sepsis causes multiple organs failures and eventually death. Changes in blood constituents due to sepsis lead to alterations in hemorheological properties, and cell adhesiveness. In this study, a new microfluidic system is proposed to measure temporal variations in biophysical properties of blood after injecting lipopolysaccharide (LPS) into a rat extracorporeal model under ex vivo condition. To measure blood viscosity, the interfacial line between blood and a reference fluid is formed in a Y-shaped channel. Based on the relation between interfacial width and pressure ratio, the temporal variation in blood viscosity is estimated. Optical images of blood flows are analyzed by decreasing flow rate for examination of red blood cell (RBC) aggregation. Platelets initiated by shear acceleration around the stenosis adhere to the post-stenosed region. By applying a correlation map that visualizes the decorrelation of the streaming blood flow, the area of adhered platelets can be quantitatively attained without labeling of platelets. To assess sepsis inflammation, conventional biomarkers (PCT and IL-8) are also monitored. The increasing tendency for blood viscosity, RBC aggregation, platelet adhesion, and septic biomarkers are observed after LPS injection. This microfluidic system would be beneficial for monitoring the changes in hemorheological properties and platelet activation caused by sepsis.Eunseop YeomHye Mi KimJun Hong ParkWoorak ChoiJunsang DohSang Joon LeeNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Eunseop Yeom
Hye Mi Kim
Jun Hong Park
Woorak Choi
Junsang Doh
Sang Joon Lee
Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
description Abstract Sepsis causes multiple organs failures and eventually death. Changes in blood constituents due to sepsis lead to alterations in hemorheological properties, and cell adhesiveness. In this study, a new microfluidic system is proposed to measure temporal variations in biophysical properties of blood after injecting lipopolysaccharide (LPS) into a rat extracorporeal model under ex vivo condition. To measure blood viscosity, the interfacial line between blood and a reference fluid is formed in a Y-shaped channel. Based on the relation between interfacial width and pressure ratio, the temporal variation in blood viscosity is estimated. Optical images of blood flows are analyzed by decreasing flow rate for examination of red blood cell (RBC) aggregation. Platelets initiated by shear acceleration around the stenosis adhere to the post-stenosed region. By applying a correlation map that visualizes the decorrelation of the streaming blood flow, the area of adhered platelets can be quantitatively attained without labeling of platelets. To assess sepsis inflammation, conventional biomarkers (PCT and IL-8) are also monitored. The increasing tendency for blood viscosity, RBC aggregation, platelet adhesion, and septic biomarkers are observed after LPS injection. This microfluidic system would be beneficial for monitoring the changes in hemorheological properties and platelet activation caused by sepsis.
format article
author Eunseop Yeom
Hye Mi Kim
Jun Hong Park
Woorak Choi
Junsang Doh
Sang Joon Lee
author_facet Eunseop Yeom
Hye Mi Kim
Jun Hong Park
Woorak Choi
Junsang Doh
Sang Joon Lee
author_sort Eunseop Yeom
title Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
title_short Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
title_full Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
title_fullStr Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
title_full_unstemmed Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats
title_sort microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in lps-injected rats
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/c9dd265acec04bbe87094de954ec8e33
work_keys_str_mv AT eunseopyeom microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
AT hyemikim microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
AT junhongpark microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
AT woorakchoi microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
AT junsangdoh microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
AT sangjoonlee microfluidicsystemformonitoringtemporalvariationsofhemorheologicalpropertiesandplateletadhesioninlpsinjectedrats
_version_ 1718394425232588800