Visual field examination method using virtual reality glasses compared with the Humphrey perimeter

Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Konstantinos Droutsas, Konstantinos Andreanos, Marilita M Moschos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a visual field examination me...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tsapakis S, Papaconstantinou D, Diagourtas A, Droutsas K, Andreanos K, Moschos MM, Brouzas D
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/c9dda2ea9e72413b8b0fb2b23f45491c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:c9dda2ea9e72413b8b0fb2b23f45491c
record_format dspace
spelling oai:doaj.org-article:c9dda2ea9e72413b8b0fb2b23f45491c2021-12-02T06:37:02ZVisual field examination method using virtual reality glasses compared with the Humphrey perimeter1177-5483https://doaj.org/article/c9dda2ea9e72413b8b0fb2b23f45491c2017-08-01T00:00:00Zhttps://www.dovepress.com/visual-field-examination-method-using-virtual-reality-glasses-compared-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Konstantinos Droutsas, Konstantinos Andreanos, Marilita M Moschos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter.Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter.Results: High correlation coefficient (r=0.808, P<0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field.Conclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use. Keywords: visual fields, virtual reality glasses, perimetry, visual fields software, smartphoneTsapakis SPapaconstantinou DDiagourtas ADroutsas KAndreanos KMoschos MMBrouzas DDove Medical PressarticleVisual fieldsvirtual reality glassesperimetryvisual fields softwaresmartphone.OphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 1431-1443 (2017)
institution DOAJ
collection DOAJ
language EN
topic Visual fields
virtual reality glasses
perimetry
visual fields software
smartphone.
Ophthalmology
RE1-994
spellingShingle Visual fields
virtual reality glasses
perimetry
visual fields software
smartphone.
Ophthalmology
RE1-994
Tsapakis S
Papaconstantinou D
Diagourtas A
Droutsas K
Andreanos K
Moschos MM
Brouzas D
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
description Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Konstantinos Droutsas, Konstantinos Andreanos, Marilita M Moschos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter.Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter.Results: High correlation coefficient (r=0.808, P<0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field.Conclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use. Keywords: visual fields, virtual reality glasses, perimetry, visual fields software, smartphone
format article
author Tsapakis S
Papaconstantinou D
Diagourtas A
Droutsas K
Andreanos K
Moschos MM
Brouzas D
author_facet Tsapakis S
Papaconstantinou D
Diagourtas A
Droutsas K
Andreanos K
Moschos MM
Brouzas D
author_sort Tsapakis S
title Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
title_short Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
title_full Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
title_fullStr Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
title_full_unstemmed Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
title_sort visual field examination method using virtual reality glasses compared with the humphrey perimeter
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/c9dda2ea9e72413b8b0fb2b23f45491c
work_keys_str_mv AT tsapakiss visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT papaconstantinoud visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT diagourtasa visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT droutsask visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT andreanosk visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT moschosmm visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
AT brouzasd visualfieldexaminationmethodusingvirtualrealityglassescomparedwiththehumphreyperimeter
_version_ 1718399838262919168