Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis
Manuel AP Vilela,1,2 Felipe M Valença,1 Pedro KM Barreto,1 Carlos EV Amaral,1 Lúcia C Pellanda1,2 1Federal University of Health Sciences of Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil; 2Institute of Cardiology, Cardiology University Foundation, Porto Alegre, Rio Gran...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ca9808b894104a0d9c44fc71dda32d10 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ca9808b894104a0d9c44fc71dda32d10 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ca9808b894104a0d9c44fc71dda32d102021-12-02T07:36:30ZAgreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis1177-5483https://doaj.org/article/ca9808b894104a0d9c44fc71dda32d102018-12-01T00:00:00Zhttps://www.dovepress.com/agreement-between-retinal-images-obtained-via-smartphones-and-images-o-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Manuel AP Vilela,1,2 Felipe M Valença,1 Pedro KM Barreto,1 Carlos EV Amaral,1 Lúcia C Pellanda1,2 1Federal University of Health Sciences of Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil; 2Institute of Cardiology, Cardiology University Foundation, Porto Alegre, Rio Grande do Sul, Brazil Background: Smartphone fundoscopy is a new option for visualizing the ocular fundus but must be validated before being included in population-based examinations. Our aim was to evaluate the quality of fundoscopic images obtained via smartphone and to compare their agreement with retinal camera images or clinical examination.Methods: The database for this study included all observational studies with smartphone fundoscopy that have comparative analyses with the gold standard methods.Results: Out of 121 potentially relevant studies, nine were included in this analysis, compris- ing a total of 4,219 eyes. Mean age was 56.6 years (SD±8.5). Combined kappa (κ) agreement statistics were equal to 77.77% (95% CI: 70.34%, 83.70%). No heterogeneity was measured by random effects (I2=zero). Conclusion: Fundoscopic images obtained by using smartphones have substantial agreement with gold standards for clinical or photographic exams.Keywords: smartphones, fundoscopy, ophthalmoscopy Vilela MAPValença FMBarreto PKMAmaral CEVPellanda LCDove Medical PressarticleSmartphonesFundoscopyOphthalmoscopyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 2581-2589 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Smartphones Fundoscopy Ophthalmoscopy Ophthalmology RE1-994 |
spellingShingle |
Smartphones Fundoscopy Ophthalmoscopy Ophthalmology RE1-994 Vilela MAP Valença FM Barreto PKM Amaral CEV Pellanda LC Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
description |
Manuel AP Vilela,1,2 Felipe M Valença,1 Pedro KM Barreto,1 Carlos EV Amaral,1 Lúcia C Pellanda1,2 1Federal University of Health Sciences of Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil; 2Institute of Cardiology, Cardiology University Foundation, Porto Alegre, Rio Grande do Sul, Brazil Background: Smartphone fundoscopy is a new option for visualizing the ocular fundus but must be validated before being included in population-based examinations. Our aim was to evaluate the quality of fundoscopic images obtained via smartphone and to compare their agreement with retinal camera images or clinical examination.Methods: The database for this study included all observational studies with smartphone fundoscopy that have comparative analyses with the gold standard methods.Results: Out of 121 potentially relevant studies, nine were included in this analysis, compris- ing a total of 4,219 eyes. Mean age was 56.6 years (SD±8.5). Combined kappa (κ) agreement statistics were equal to 77.77% (95% CI: 70.34%, 83.70%). No heterogeneity was measured by random effects (I2=zero). Conclusion: Fundoscopic images obtained by using smartphones have substantial agreement with gold standards for clinical or photographic exams.Keywords: smartphones, fundoscopy, ophthalmoscopy |
format |
article |
author |
Vilela MAP Valença FM Barreto PKM Amaral CEV Pellanda LC |
author_facet |
Vilela MAP Valença FM Barreto PKM Amaral CEV Pellanda LC |
author_sort |
Vilela MAP |
title |
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
title_short |
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
title_full |
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
title_fullStr |
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
title_full_unstemmed |
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
title_sort |
agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams – systematic review and meta-analysis |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/ca9808b894104a0d9c44fc71dda32d10 |
work_keys_str_mv |
AT vilelamap agreementbetweenretinalimagesobtainedviasmartphonesandimagesobtainedwithretinalcamerasorfundoscopicexamsndashsystematicreviewandmetaanalysis AT valencafm agreementbetweenretinalimagesobtainedviasmartphonesandimagesobtainedwithretinalcamerasorfundoscopicexamsndashsystematicreviewandmetaanalysis AT barretopkm agreementbetweenretinalimagesobtainedviasmartphonesandimagesobtainedwithretinalcamerasorfundoscopicexamsndashsystematicreviewandmetaanalysis AT amaralcev agreementbetweenretinalimagesobtainedviasmartphonesandimagesobtainedwithretinalcamerasorfundoscopicexamsndashsystematicreviewandmetaanalysis AT pellandalc agreementbetweenretinalimagesobtainedviasmartphonesandimagesobtainedwithretinalcamerasorfundoscopicexamsndashsystematicreviewandmetaanalysis |
_version_ |
1718399366579879936 |