Photogrammetric analysis of postextraction space closure

Introduction: When planning orthodontic treatment, it is sometimes necessary to apply the extraction of individual teeth, in order to achieve proper occlusion and an acceptable aesthetic appearance. Clinicians give the greatest advantage to elastic chains as a method for post-extraction space closur...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Umićević-Davidović Mirjana, Arapović-Savić Marijana, Arbutina Adriana, Adamović Tijana, Đukić Igor
Formato: article
Lenguaje:EN
SR
Publicado: Serbian Medical Society - Dental Section, Belgrade 2021
Materias:
Acceso en línea:https://doaj.org/article/cadb666358f24620898c39e6784b8209
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:cadb666358f24620898c39e6784b8209
record_format dspace
spelling oai:doaj.org-article:cadb666358f24620898c39e6784b82092021-12-05T21:33:40ZPhotogrammetric analysis of postextraction space closure0039-17431452-370110.2298/SGS2102059Uhttps://doaj.org/article/cadb666358f24620898c39e6784b82092021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/0039-1743/2021/0039-17432102059U.pdfhttps://doaj.org/toc/0039-1743https://doaj.org/toc/1452-3701Introduction: When planning orthodontic treatment, it is sometimes necessary to apply the extraction of individual teeth, in order to achieve proper occlusion and an acceptable aesthetic appearance. Clinicians give the greatest advantage to elastic chains as a method for post-extraction space closure during treatment with fixed orthodontic appliances. When closing post-extraction spaces, it is necessary to measure them in order to adjust the treatment plan. One of the most acceptable methods is photogrammetry. The aim of this study was to analyze, using a photogrammetric method, the efficacy of post-extraction space closure with elastic chains during orthodontic treatment with fixed orthodontic appliances. Material and Methods: The total sample in study consisted of 38 post-extraction spaces in 19 patients who were indicated for first premolars extraction and use of fixed orthodontic appliances in order to achieve treatment goal. Elastic chains were used to close post-extraction spaces. Post-extraction sites were monitored for 6 months with follow-up examinations every 4 weeks. Mechanisms were activated at controlled examinations, and measurements of the width of post-extraction spaces were performed by photogrammetry and digital caliper. Results: The results showed that average reduction of post-extraction space width was 1.00 mm per month by photogrammetric measurement, while the average values of measurements with a digital caliper were 1.02 mm. The average values were measured in six time intervals and a statistically significant change in average intervals of post-extraction spaces during 6 months was determined. Conclusion The elastic chain has proven to be a very effective mechanism for closing post-extraction space, and photogrammetry as a simple and precise method for monitoring results of treatment. Since the difference in relation to measurements with a digital caliper is minimal, photogrammetry can be routinely applied in everyday practice.Umićević-Davidović MirjanaArapović-Savić MarijanaArbutina AdrianaAdamović TijanaĐukić IgorSerbian Medical Society - Dental Section, Belgradearticlephotogrammetryelastic chainpost-extraction spaceDentistryRK1-715ENSRStomatološki glasnik Srbije, Vol 68, Iss 2, Pp 59-67 (2021)
institution DOAJ
collection DOAJ
language EN
SR
topic photogrammetry
elastic chain
post-extraction space
Dentistry
RK1-715
spellingShingle photogrammetry
elastic chain
post-extraction space
Dentistry
RK1-715
Umićević-Davidović Mirjana
Arapović-Savić Marijana
Arbutina Adriana
Adamović Tijana
Đukić Igor
Photogrammetric analysis of postextraction space closure
description Introduction: When planning orthodontic treatment, it is sometimes necessary to apply the extraction of individual teeth, in order to achieve proper occlusion and an acceptable aesthetic appearance. Clinicians give the greatest advantage to elastic chains as a method for post-extraction space closure during treatment with fixed orthodontic appliances. When closing post-extraction spaces, it is necessary to measure them in order to adjust the treatment plan. One of the most acceptable methods is photogrammetry. The aim of this study was to analyze, using a photogrammetric method, the efficacy of post-extraction space closure with elastic chains during orthodontic treatment with fixed orthodontic appliances. Material and Methods: The total sample in study consisted of 38 post-extraction spaces in 19 patients who were indicated for first premolars extraction and use of fixed orthodontic appliances in order to achieve treatment goal. Elastic chains were used to close post-extraction spaces. Post-extraction sites were monitored for 6 months with follow-up examinations every 4 weeks. Mechanisms were activated at controlled examinations, and measurements of the width of post-extraction spaces were performed by photogrammetry and digital caliper. Results: The results showed that average reduction of post-extraction space width was 1.00 mm per month by photogrammetric measurement, while the average values of measurements with a digital caliper were 1.02 mm. The average values were measured in six time intervals and a statistically significant change in average intervals of post-extraction spaces during 6 months was determined. Conclusion The elastic chain has proven to be a very effective mechanism for closing post-extraction space, and photogrammetry as a simple and precise method for monitoring results of treatment. Since the difference in relation to measurements with a digital caliper is minimal, photogrammetry can be routinely applied in everyday practice.
format article
author Umićević-Davidović Mirjana
Arapović-Savić Marijana
Arbutina Adriana
Adamović Tijana
Đukić Igor
author_facet Umićević-Davidović Mirjana
Arapović-Savić Marijana
Arbutina Adriana
Adamović Tijana
Đukić Igor
author_sort Umićević-Davidović Mirjana
title Photogrammetric analysis of postextraction space closure
title_short Photogrammetric analysis of postextraction space closure
title_full Photogrammetric analysis of postextraction space closure
title_fullStr Photogrammetric analysis of postextraction space closure
title_full_unstemmed Photogrammetric analysis of postextraction space closure
title_sort photogrammetric analysis of postextraction space closure
publisher Serbian Medical Society - Dental Section, Belgrade
publishDate 2021
url https://doaj.org/article/cadb666358f24620898c39e6784b8209
work_keys_str_mv AT umicevicdavidovicmirjana photogrammetricanalysisofpostextractionspaceclosure
AT arapovicsavicmarijana photogrammetricanalysisofpostextractionspaceclosure
AT arbutinaadriana photogrammetricanalysisofpostextractionspaceclosure
AT adamovictijana photogrammetricanalysisofpostextractionspaceclosure
AT đukicigor photogrammetricanalysisofpostextractionspaceclosure
_version_ 1718370970793672704