Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery

Ali Simsek,1 Süleyman Ciftci21Department of Ophthalmology, Faculty of Medicine, Adiyaman University, Adiyaman, Turkey; 2Department of Ophthalmology, Diyarbakir Training and Research Hospital, Diyarbakir, TurkeyBackground: The aim of this study was to assess the value of ultrasonic biomi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ciftci S, Simsek A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://doaj.org/article/cd239365c0f9440397c123b2c697d1aa
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:cd239365c0f9440397c123b2c697d1aa
record_format dspace
spelling oai:doaj.org-article:cd239365c0f9440397c123b2c697d1aa2021-12-02T00:53:15ZEvaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery1177-54671177-5483https://doaj.org/article/cd239365c0f9440397c123b2c697d1aa2012-11-01T00:00:00Zhttp://www.dovepress.com/evaluation-of-ultrasonic-biomicroscopy-results-in-anterior-eye-segment-a11568https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Ali Simsek,1 Süleyman Ciftci21Department of Ophthalmology, Faculty of Medicine, Adiyaman University, Adiyaman, Turkey; 2Department of Ophthalmology, Diyarbakir Training and Research Hospital, Diyarbakir, TurkeyBackground: The aim of this study was to assess the value of ultrasonic biomicroscopy in reporting decreases in intraocular pressure resulting from changes in anterior chamber depth and angle after phacoemulsification and intracapsular lens implantation in patients with cataract.Methods: This prospective interventional case series included 50 eyes of 50 consecutive subjects operated at the same center. Patients with eye disease affecting visual acuity, a history of eye surgery, corneal surface irregularities, a pupil diameter < 5 mm after preoperative dilation, aged younger than 35 years, posterior capsule perforation, iris dialysis during surgery, intensive postoperative corneal edema, and inability to attend adequate follow-up were excluded. Intraocular pressure, anterior chamber depth and angle, and corneal thickness were measured before and one month after surgery.Results: The mean preoperative intraocular pressure was 14 mmHg and postoperatively was 11 mmHg. Mean anterior chamber depth preoperatively was 2.8 mm and increased to 3.7 mm postoperatively. The mean anterior chamber angle was measured as 27° preoperatively and as 42° postoperatively.Conclusion: After phacoemulsification and intracapsular lens implantation, ultrasonic biomicroscopy showed that the iris diaphragm had shifted backwards, widening the angle of the anterior chamber and decreasing intraocular pressure.Keywords: anterior chamber depth, anterior chamber angle, ultrasonic biomicroscopyCiftci SSimsek ADove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 1931-1934 (2012)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Ciftci S
Simsek A
Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
description Ali Simsek,1 Süleyman Ciftci21Department of Ophthalmology, Faculty of Medicine, Adiyaman University, Adiyaman, Turkey; 2Department of Ophthalmology, Diyarbakir Training and Research Hospital, Diyarbakir, TurkeyBackground: The aim of this study was to assess the value of ultrasonic biomicroscopy in reporting decreases in intraocular pressure resulting from changes in anterior chamber depth and angle after phacoemulsification and intracapsular lens implantation in patients with cataract.Methods: This prospective interventional case series included 50 eyes of 50 consecutive subjects operated at the same center. Patients with eye disease affecting visual acuity, a history of eye surgery, corneal surface irregularities, a pupil diameter < 5 mm after preoperative dilation, aged younger than 35 years, posterior capsule perforation, iris dialysis during surgery, intensive postoperative corneal edema, and inability to attend adequate follow-up were excluded. Intraocular pressure, anterior chamber depth and angle, and corneal thickness were measured before and one month after surgery.Results: The mean preoperative intraocular pressure was 14 mmHg and postoperatively was 11 mmHg. Mean anterior chamber depth preoperatively was 2.8 mm and increased to 3.7 mm postoperatively. The mean anterior chamber angle was measured as 27° preoperatively and as 42° postoperatively.Conclusion: After phacoemulsification and intracapsular lens implantation, ultrasonic biomicroscopy showed that the iris diaphragm had shifted backwards, widening the angle of the anterior chamber and decreasing intraocular pressure.Keywords: anterior chamber depth, anterior chamber angle, ultrasonic biomicroscopy
format article
author Ciftci S
Simsek A
author_facet Ciftci S
Simsek A
author_sort Ciftci S
title Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
title_short Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
title_full Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
title_fullStr Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
title_full_unstemmed Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
title_sort evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery
publisher Dove Medical Press
publishDate 2012
url https://doaj.org/article/cd239365c0f9440397c123b2c697d1aa
work_keys_str_mv AT ciftcis evaluationofultrasonicbiomicroscopyresultsinanterioreyesegmentbeforeandaftercataractsurgery
AT simseka evaluationofultrasonicbiomicroscopyresultsinanterioreyesegmentbeforeandaftercataractsurgery
_version_ 1718403465573564416