RISK TO BE INFECTED BY PROVISIONALLY PATHOGENIC MICROORGANISMS, MOLD AND YEASTS IN URBAN ENVIRONMENT
Abstract. The samples of air were taken in 122 shops with the split air conditioning systems. The unfavorable changes of air quality were detected after switching of air-conditioning systems. Before switching of the air-conditioning systems, the provisionally pathogenic and pathogenic bacteria in th...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | RU |
Publicado: |
Sankt-Peterburg : NIIÈM imeni Pastera
2014
|
Materias: | |
Acceso en línea: | https://doaj.org/article/cdc234086333427c922832c5e133ba3b |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | Abstract. The samples of air were taken in 122 shops with the split air conditioning systems. The unfavorable changes of air quality were detected after switching of air-conditioning systems. Before switching of the air-conditioning systems, the provisionally pathogenic and pathogenic bacteria in the air were presented in 6.4% of samples, the mould fungi — in 27.8%, the yeast fungi — in 5.7%. After 30 minutes of split-systems operation, the provisionally pathogenic and pathogenic bacteria were found in 97.5% samples, mould fungi — in 72.1% and the yeast fungi — in 27.9%. Moreover, the species diversity of microorganisms in indoor air, after switching of split-system, was fully corresponded (100%) to the microflora of biofilms in internal block of the split-systems. Variants, in which microorganisms isolated from the biofilm in the condensate removal system after the switching split-systems was absent in premises air, were not determined. Thus, the microflora, which forms the biofilm in the condensate removal system, is a source of air pollution in the premises, where the split system were installed. |
---|