Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition

In order to solve the problem that the fault line cannot be accurately identified after single-phase grounding fault occurs in power grid,an intelligent sensing method of residual current grounding fault based on wavelet packet decomposition was proposed.Based on wavelet analysis and intelligent sen...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bingyu LI, Xuhao DU, Junjie MIAO, Haobin WANG, Yanqiang MA, Zheng LI
Formato: article
Lenguaje:ZH
Publicado: Hebei University of Science and Technology 2021
Materias:
T
Acceso en línea:https://doaj.org/article/ceace0c146f34d549918063a1caf85cb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ceace0c146f34d549918063a1caf85cb
record_format dspace
spelling oai:doaj.org-article:ceace0c146f34d549918063a1caf85cb2021-11-23T07:08:47ZResidual current grounding fault intelligent sensing technology based on wavelet packet decomposition1008-154210.7535/hbkd.2021yx03007https://doaj.org/article/ceace0c146f34d549918063a1caf85cb2021-06-01T00:00:00Zhttp://xuebao.hebust.edu.cn/hbkjdx/ch/reader/create_pdf.aspx?file_no=b202103007&flag=1&journal_https://doaj.org/toc/1008-1542In order to solve the problem that the fault line cannot be accurately identified after single-phase grounding fault occurs in power grid,an intelligent sensing method of residual current grounding fault based on wavelet packet decomposition was proposed.Based on wavelet analysis and intelligent sensing principle,the residual current generated by grounding fault was collected,and the collected residual current information was analyzed and compared to sense the grounding fault and identify the fault.By researching on-line monitoring of residual current of AC power supply and arc grounding fault diagnosis technology which is based on wavelet transform,the time-frequency characteristics of current obtained by wavelet packet decomposition were used for fault line selection;the fault line selection method based on the proposed wavelet packet decomposition was simulated.The results show that the time-frequency information can be extracted accurately and the fault line can be determined effectively by using the method,and the fault line can be accurately identified with the difference of current characteristics between fault line and normal line.The research result provides a reference for the design of intelligent sensing system of AC power grounding fault.Bingyu LIXuhao DUJunjie MIAOHaobin WANGYanqiang MAZheng LIHebei University of Science and Technologyarticleelectric energy; residual current; wavelet analysis; ground fault; intelligent perception; fault line selectionTechnologyTZHJournal of Hebei University of Science and Technology, Vol 42, Iss 3, Pp 257-264 (2021)
institution DOAJ
collection DOAJ
language ZH
topic electric energy; residual current; wavelet analysis; ground fault; intelligent perception; fault line selection
Technology
T
spellingShingle electric energy; residual current; wavelet analysis; ground fault; intelligent perception; fault line selection
Technology
T
Bingyu LI
Xuhao DU
Junjie MIAO
Haobin WANG
Yanqiang MA
Zheng LI
Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
description In order to solve the problem that the fault line cannot be accurately identified after single-phase grounding fault occurs in power grid,an intelligent sensing method of residual current grounding fault based on wavelet packet decomposition was proposed.Based on wavelet analysis and intelligent sensing principle,the residual current generated by grounding fault was collected,and the collected residual current information was analyzed and compared to sense the grounding fault and identify the fault.By researching on-line monitoring of residual current of AC power supply and arc grounding fault diagnosis technology which is based on wavelet transform,the time-frequency characteristics of current obtained by wavelet packet decomposition were used for fault line selection;the fault line selection method based on the proposed wavelet packet decomposition was simulated.The results show that the time-frequency information can be extracted accurately and the fault line can be determined effectively by using the method,and the fault line can be accurately identified with the difference of current characteristics between fault line and normal line.The research result provides a reference for the design of intelligent sensing system of AC power grounding fault.
format article
author Bingyu LI
Xuhao DU
Junjie MIAO
Haobin WANG
Yanqiang MA
Zheng LI
author_facet Bingyu LI
Xuhao DU
Junjie MIAO
Haobin WANG
Yanqiang MA
Zheng LI
author_sort Bingyu LI
title Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
title_short Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
title_full Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
title_fullStr Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
title_full_unstemmed Residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
title_sort residual current grounding fault intelligent sensing technology based on wavelet packet decomposition
publisher Hebei University of Science and Technology
publishDate 2021
url https://doaj.org/article/ceace0c146f34d549918063a1caf85cb
work_keys_str_mv AT bingyuli residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
AT xuhaodu residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
AT junjiemiao residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
AT haobinwang residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
AT yanqiangma residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
AT zhengli residualcurrentgroundingfaultintelligentsensingtechnologybasedonwaveletpacketdecomposition
_version_ 1718416910572322816