Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay

Ting Xu, Qiang Zhang, Ya-han Fan, Ru-qing Li, Hua Lu, Shu-ming Zhao, Tian-lun Jiang Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Chongqing, People’s Republic of China Background: Accurate and reliable blood grouping is essential for safe bloo...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Xu T, Zhang Q, Fan YH, Li RQ, Lu H, Zhao SM, Jiang TL
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/ceef5c9080b94df3badc3eddd43fd99e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ceef5c9080b94df3badc3eddd43fd99e
record_format dspace
spelling oai:doaj.org-article:ceef5c9080b94df3badc3eddd43fd99e2021-12-02T02:35:13ZQuantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay1178-2013https://doaj.org/article/ceef5c9080b94df3badc3eddd43fd99e2017-04-01T00:00:00Zhttps://www.dovepress.com/quantitative-and-multiplexed-detection-for-blood-typing-based-on-quant-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Ting Xu, Qiang Zhang, Ya-han Fan, Ru-qing Li, Hua Lu, Shu-ming Zhao, Tian-lun Jiang Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Chongqing, People’s Republic of China Background: Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads.Methods: In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples.Results: Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 105 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively.Conclusion: In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety. Keywords: blood typing, quantum dots, magnetic beads, blood group antigens, fluorescence detectionXu TZhang QFan YHLi RQLu HZhao SMJiang TLDove Medical PressarticleBlood typingQuantum dotsmagnetic beadsBlood group antigensFluorescence detectionMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol Volume 12, Pp 3347-3356 (2017)
institution DOAJ
collection DOAJ
language EN
topic Blood typing
Quantum dots
magnetic beads
Blood group antigens
Fluorescence detection
Medicine (General)
R5-920
spellingShingle Blood typing
Quantum dots
magnetic beads
Blood group antigens
Fluorescence detection
Medicine (General)
R5-920
Xu T
Zhang Q
Fan YH
Li RQ
Lu H
Zhao SM
Jiang TL
Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
description Ting Xu, Qiang Zhang, Ya-han Fan, Ru-qing Li, Hua Lu, Shu-ming Zhao, Tian-lun Jiang Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Chongqing, People’s Republic of China Background: Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads.Methods: In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples.Results: Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 105 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively.Conclusion: In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety. Keywords: blood typing, quantum dots, magnetic beads, blood group antigens, fluorescence detection
format article
author Xu T
Zhang Q
Fan YH
Li RQ
Lu H
Zhao SM
Jiang TL
author_facet Xu T
Zhang Q
Fan YH
Li RQ
Lu H
Zhao SM
Jiang TL
author_sort Xu T
title Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
title_short Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
title_full Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
title_fullStr Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
title_full_unstemmed Quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
title_sort quantitative and multiplexed detection for blood typing based on quantum dot–magnetic bead assay
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/ceef5c9080b94df3badc3eddd43fd99e
work_keys_str_mv AT xut quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT zhangq quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT fanyh quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT lirq quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT luh quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT zhaosm quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
AT jiangtl quantitativeandmultiplexeddetectionforbloodtypingbasedonquantumdotndashmagneticbeadassay
_version_ 1718402376321204224