New strategies for base frame fabrication in microtia reconstruction

Abstract The base frame provides a stable support for the helix, antihelix, and tragus–antitragus complex in microtia reconstruction, and this support is vital to attain a highly defined outline for a reconstructed auricle. The success of base frame sculpting depends on appropriate treatment of the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yiyuan Li, Datao Li, Zhicheng Xu, Ruhong Zhang, Qun Zhang, Feng Xu, Xia Chen
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/cf033bfb3c73419695e0897bbc5971e6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:cf033bfb3c73419695e0897bbc5971e6
record_format dspace
spelling oai:doaj.org-article:cf033bfb3c73419695e0897bbc5971e62021-12-02T17:06:09ZNew strategies for base frame fabrication in microtia reconstruction10.1038/s41598-021-95613-32045-2322https://doaj.org/article/cf033bfb3c73419695e0897bbc5971e62021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-95613-3https://doaj.org/toc/2045-2322Abstract The base frame provides a stable support for the helix, antihelix, and tragus–antitragus complex in microtia reconstruction, and this support is vital to attain a highly defined outline for a reconstructed auricle. The success of base frame sculpting depends on appropriate treatment of the cartilage, mainly the sixth and seventh costal cartilages, which may have different characteristics. The aim of this study was to demonstrate the relevant details for base frame fabrication under various scenarios. Between 2016 and 2019, a total of 352 patients with microtia underwent autologous auricular reconstruction. Concerning the different sizes and characteristics of the costal cartilage used for the base frame reconstruction, we describe the related methods for fabrication and introduce corresponding strategies for proper management. We found that 90% of the patients responded at follow-up, and 76% of them were satisfied with the cosmetically refined auricle with harmonious integrity. The elaborate design and appropriate utilization of costal cartilage for base frame sculpting is one of the most significant and fundamental processes in microtia reconstruction. It contributes to achieving a clearly defined outline of the auricle with harmonious integrity, which is as important as the other projected subunits.Yiyuan LiDatao LiZhicheng XuRuhong ZhangQun ZhangFeng XuXia ChenNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Yiyuan Li
Datao Li
Zhicheng Xu
Ruhong Zhang
Qun Zhang
Feng Xu
Xia Chen
New strategies for base frame fabrication in microtia reconstruction
description Abstract The base frame provides a stable support for the helix, antihelix, and tragus–antitragus complex in microtia reconstruction, and this support is vital to attain a highly defined outline for a reconstructed auricle. The success of base frame sculpting depends on appropriate treatment of the cartilage, mainly the sixth and seventh costal cartilages, which may have different characteristics. The aim of this study was to demonstrate the relevant details for base frame fabrication under various scenarios. Between 2016 and 2019, a total of 352 patients with microtia underwent autologous auricular reconstruction. Concerning the different sizes and characteristics of the costal cartilage used for the base frame reconstruction, we describe the related methods for fabrication and introduce corresponding strategies for proper management. We found that 90% of the patients responded at follow-up, and 76% of them were satisfied with the cosmetically refined auricle with harmonious integrity. The elaborate design and appropriate utilization of costal cartilage for base frame sculpting is one of the most significant and fundamental processes in microtia reconstruction. It contributes to achieving a clearly defined outline of the auricle with harmonious integrity, which is as important as the other projected subunits.
format article
author Yiyuan Li
Datao Li
Zhicheng Xu
Ruhong Zhang
Qun Zhang
Feng Xu
Xia Chen
author_facet Yiyuan Li
Datao Li
Zhicheng Xu
Ruhong Zhang
Qun Zhang
Feng Xu
Xia Chen
author_sort Yiyuan Li
title New strategies for base frame fabrication in microtia reconstruction
title_short New strategies for base frame fabrication in microtia reconstruction
title_full New strategies for base frame fabrication in microtia reconstruction
title_fullStr New strategies for base frame fabrication in microtia reconstruction
title_full_unstemmed New strategies for base frame fabrication in microtia reconstruction
title_sort new strategies for base frame fabrication in microtia reconstruction
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/cf033bfb3c73419695e0897bbc5971e6
work_keys_str_mv AT yiyuanli newstrategiesforbaseframefabricationinmicrotiareconstruction
AT dataoli newstrategiesforbaseframefabricationinmicrotiareconstruction
AT zhichengxu newstrategiesforbaseframefabricationinmicrotiareconstruction
AT ruhongzhang newstrategiesforbaseframefabricationinmicrotiareconstruction
AT qunzhang newstrategiesforbaseframefabricationinmicrotiareconstruction
AT fengxu newstrategiesforbaseframefabricationinmicrotiareconstruction
AT xiachen newstrategiesforbaseframefabricationinmicrotiareconstruction
_version_ 1718381758398857216