Abstract Short wavelength automated perimetry (SWAP) is known for detecting the early reduction of retinal sensitivity (RS) in glaucoma. It’s application in retinal diseases have also been discussed previously. We investigated the difference in RS measured between standard white-on-white automated p...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Han Peng Zhou, Ryo Asaoka, Tatsuya Inoue, Shotaro Asano, Hiroshi Murata, Takumi Hara, So Makino, Kazuaki Kadonosono, Ryo Obata
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/d07716e3e76b42d09a91a4fd6bfad8a9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d07716e3e76b42d09a91a4fd6bfad8a9
record_format dspace
spelling oai:doaj.org-article:d07716e3e76b42d09a91a4fd6bfad8a92021-12-02T18:37:06ZShort wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy10.1038/s41598-020-73569-02045-2322https://doaj.org/article/d07716e3e76b42d09a91a4fd6bfad8a92020-10-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-73569-0https://doaj.org/toc/2045-2322Abstract Short wavelength automated perimetry (SWAP) is known for detecting the early reduction of retinal sensitivity (RS) in glaucoma. It’s application in retinal diseases have also been discussed previously. We investigated the difference in RS measured between standard white-on-white automated perimetry (WW) and blue-on-yellow SWAP in central serous chorioretinopathy (CSC). The overall RS (W-RS, S-RS) as well as the RS inside and outside of the serous retinal detachment (SRD) region were investigated in 26 eyes of 26 CSC patients using WW and SWAP. The central retinal thickness, central choroidal thickness, SRD area (SRDa), and SRD height at the fovea were measured using optic coherence tomography. RS inside the SRD region was lower than that of outside for both perimetries (both p < 0.001). The difference between RS inside and outside of the SRD region was greater in SWAP compared to WW (p < 0.001). Univariate analysis revealed significant correlations between SRDa and both W-RS and S-RS (both p < 0.001); moreover, multivariate analysis indicated that only S-RS was selected as the optimal model for SRDa. Our study demonstrated that SWAP was detected the decrease in RS more accurately than WW in CSC. These results may suggest the usefulness of SWAP for detecting change of retinal function in CSC.Han Peng ZhouRyo AsaokaTatsuya InoueShotaro AsanoHiroshi MurataTakumi HaraSo MakinoKazuaki KadonosonoRyo ObataNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-8 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Han Peng Zhou
Ryo Asaoka
Tatsuya Inoue
Shotaro Asano
Hiroshi Murata
Takumi Hara
So Makino
Kazuaki Kadonosono
Ryo Obata
Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
description Abstract Short wavelength automated perimetry (SWAP) is known for detecting the early reduction of retinal sensitivity (RS) in glaucoma. It’s application in retinal diseases have also been discussed previously. We investigated the difference in RS measured between standard white-on-white automated perimetry (WW) and blue-on-yellow SWAP in central serous chorioretinopathy (CSC). The overall RS (W-RS, S-RS) as well as the RS inside and outside of the serous retinal detachment (SRD) region were investigated in 26 eyes of 26 CSC patients using WW and SWAP. The central retinal thickness, central choroidal thickness, SRD area (SRDa), and SRD height at the fovea were measured using optic coherence tomography. RS inside the SRD region was lower than that of outside for both perimetries (both p < 0.001). The difference between RS inside and outside of the SRD region was greater in SWAP compared to WW (p < 0.001). Univariate analysis revealed significant correlations between SRDa and both W-RS and S-RS (both p < 0.001); moreover, multivariate analysis indicated that only S-RS was selected as the optimal model for SRDa. Our study demonstrated that SWAP was detected the decrease in RS more accurately than WW in CSC. These results may suggest the usefulness of SWAP for detecting change of retinal function in CSC.
format article
author Han Peng Zhou
Ryo Asaoka
Tatsuya Inoue
Shotaro Asano
Hiroshi Murata
Takumi Hara
So Makino
Kazuaki Kadonosono
Ryo Obata
author_facet Han Peng Zhou
Ryo Asaoka
Tatsuya Inoue
Shotaro Asano
Hiroshi Murata
Takumi Hara
So Makino
Kazuaki Kadonosono
Ryo Obata
author_sort Han Peng Zhou
title Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
title_short Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
title_full Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
title_fullStr Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
title_full_unstemmed Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
title_sort short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/d07716e3e76b42d09a91a4fd6bfad8a9
work_keys_str_mv AT hanpengzhou shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT ryoasaoka shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT tatsuyainoue shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT shotaroasano shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT hiroshimurata shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT takumihara shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT somakino shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT kazuakikadonosono shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
AT ryoobata shortwavelengthautomatedperimetryandstandardautomatedperimetryincentralserouschorioretinopathy
_version_ 1718377827291627520