Comparable Efficacy in Ischemic and Non-Ischemic ICD Recipients for the Primary Prevention of Sudden Cardiac Death

(1) Background: In patients suffering from heart failure, the main causes of death are either hemodynamic failure, or ventricular arrhythmias. The only tool to significantly reduce arrhythmic sudden death is the implantable cardioverter defibrillator (ICD), but not all patients benefit to the same e...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Andreea Maria Ursaru, Antoniu Octavian Petris, Irina Iuliana Costache, Nicolae Dan Tesloianu
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/d09d9434b76d46c29bd2110a555121e5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:(1) Background: In patients suffering from heart failure, the main causes of death are either hemodynamic failure, or ventricular arrhythmias. The only tool to significantly reduce arrhythmic sudden death is the implantable cardioverter defibrillator (ICD), but not all patients benefit to the same extent from these devices. (2) Methods: The primary outcome of this single-center study was defined as cardiovascular death in patients with ischemic and non-ischemic heart failure who have benefited from ICD therapy. The secondary outcomes were death from any cause, sudden cardiac death, ICD-related therapies (appropriate antitachycardia pacing or shock therapy for ventricular tachycardia or fibrillation) and recurrences of ventricular tachyarrhythmias. (3) Results: A total of 403 consecutive ICD recipients—symptomatic heart failure patients with ICD for the primary prevention of sudden cardiac death—were included retrospectively: 59% ischemic cardiomyopathy (ICMP) and 41% non-ischemic cardiomyopathy (NICMP) patients. Within a median follow-up period of 36 months, the incidence of cardiovascular mortality was not significantly different in patients with NICMP and ICMP: the primary outcome had occurred in 9 patients (5.4%) in the NICMP group and in 14 patients (5.9%) in the ICMP group (hazard ratio 1; 95% confidence interval (CI) 0.45 to 2.28; <i>p</i> = 0.97). All-cause mortality occurred in 14 of 166 patients (8.4%) in the NICMP group and 18 of 237 patients (7.6%) in the ICMP group. Sudden cardiac death occurred in two patients (1.2%) in the NICMP group and in four patients (1.7%) in the ICMP group (hazard ratio 0.71; 95% CI, 0.13 to 3.88; <i>p</i> = 0.69). The rate of appropriate device therapies was comparable in both groups. (4) Conclusions: In this study, ICD implantation for primary prevention of sudden cardiac death in patients with symptomatic systolic heart failure was associated with similar rates of cardiovascular and all-cause mortality in patients with ischemic heart disease, and in patients with heart failure from other causes. NICMP and ICMP showed comparable rates of recurrent ventricular tachyarrhythmias and appropriate ICD therapies.