Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system

Abstract Legionnaires’ disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate method...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Nobuyasu Yamaguchi, Yusuke Tokunaga, Satoko Goto, Yudai Fujii, Fumiya Banno, Akiko Edagawa
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/d14c957a482440a3b6f5e94c6876b062
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d14c957a482440a3b6f5e94c6876b062
record_format dspace
spelling oai:doaj.org-article:d14c957a482440a3b6f5e94c6876b0622021-12-02T11:52:37ZRapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system10.1038/s41598-017-03293-92045-2322https://doaj.org/article/d14c957a482440a3b6f5e94c6876b0622017-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-03293-9https://doaj.org/toc/2045-2322Abstract Legionnaires’ disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5–3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.Nobuyasu YamaguchiYusuke TokunagaSatoko GotoYudai FujiiFumiya BannoAkiko EdagawaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-8 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Nobuyasu Yamaguchi
Yusuke Tokunaga
Satoko Goto
Yudai Fujii
Fumiya Banno
Akiko Edagawa
Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
description Abstract Legionnaires’ disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5–3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
format article
author Nobuyasu Yamaguchi
Yusuke Tokunaga
Satoko Goto
Yudai Fujii
Fumiya Banno
Akiko Edagawa
author_facet Nobuyasu Yamaguchi
Yusuke Tokunaga
Satoko Goto
Yudai Fujii
Fumiya Banno
Akiko Edagawa
author_sort Nobuyasu Yamaguchi
title Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
title_short Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
title_full Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
title_fullStr Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
title_full_unstemmed Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
title_sort rapid on-site monitoring of legionella pneumophila in cooling tower water using a portable microfluidic system
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/d14c957a482440a3b6f5e94c6876b062
work_keys_str_mv AT nobuyasuyamaguchi rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
AT yusuketokunaga rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
AT satokogoto rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
AT yudaifujii rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
AT fumiyabanno rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
AT akikoedagawa rapidonsitemonitoringoflegionellapneumophilaincoolingtowerwaterusingaportablemicrofluidicsystem
_version_ 1718395012433051648