Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera

CVD Diamond Detectors are going to be used in a number of neutron diagnostics of the International Thermonuclear Experimental Reactor (ITER) during its power operation phase [1]. One of such diagnostics is the Vertical Neutron Camera (VNC), which is being developed by the ITER Russian Domestic Agenc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Zhuravlev Michael, Nemtcev Grigorii, Nagornyi Nikita, Meshchaninov Sergey, Rodionov Roman, Mironov Andrey, Zvonareva Anzhela, Mironova Ekaterina, Portone Sergey
Formato: article
Lenguaje:EN
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/d1bbc67bc8914e86b0e014f9b053c460
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d1bbc67bc8914e86b0e014f9b053c460
record_format dspace
spelling oai:doaj.org-article:d1bbc67bc8914e86b0e014f9b053c4602021-12-02T17:12:45ZDevelopment of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera2100-014X10.1051/epjconf/202125303002https://doaj.org/article/d1bbc67bc8914e86b0e014f9b053c4602021-01-01T00:00:00Zhttps://www.epj-conferences.org/articles/epjconf/pdf/2021/07/epjconf_animma2021_03002.pdfhttps://doaj.org/toc/2100-014XCVD Diamond Detectors are going to be used in a number of neutron diagnostics of the International Thermonuclear Experimental Reactor (ITER) during its power operation phase [1]. One of such diagnostics is the Vertical Neutron Camera (VNC), which is being developed by the ITER Russian Domestic Agency (Institution “Project Center ITER”). In VNC Diamond detectors are used for real-time neutron flux and neutron spectrum measurements. In this paper we present current advancements in the development of a digital signal processing unit for the VNC diamond detector measurement channel. We give an overview of the signal properties, hardware requirements and firmware/software solutions used in the current version of the signal processing unit. We also present preliminary test results for this measurement system and explain the discovered problems and possible solutions.Zhuravlev MichaelNemtcev GrigoriiNagornyi NikitaMeshchaninov SergeyRodionov RomanMironov AndreyZvonareva AnzhelaMironova EkaterinaPortone SergeyEDP Sciencesarticleitervertical neutron cameracvd diamond detectordigital signal processingPhysicsQC1-999ENEPJ Web of Conferences, Vol 253, p 03002 (2021)
institution DOAJ
collection DOAJ
language EN
topic iter
vertical neutron camera
cvd diamond detector
digital signal processing
Physics
QC1-999
spellingShingle iter
vertical neutron camera
cvd diamond detector
digital signal processing
Physics
QC1-999
Zhuravlev Michael
Nemtcev Grigorii
Nagornyi Nikita
Meshchaninov Sergey
Rodionov Roman
Mironov Andrey
Zvonareva Anzhela
Mironova Ekaterina
Portone Sergey
Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
description CVD Diamond Detectors are going to be used in a number of neutron diagnostics of the International Thermonuclear Experimental Reactor (ITER) during its power operation phase [1]. One of such diagnostics is the Vertical Neutron Camera (VNC), which is being developed by the ITER Russian Domestic Agency (Institution “Project Center ITER”). In VNC Diamond detectors are used for real-time neutron flux and neutron spectrum measurements. In this paper we present current advancements in the development of a digital signal processing unit for the VNC diamond detector measurement channel. We give an overview of the signal properties, hardware requirements and firmware/software solutions used in the current version of the signal processing unit. We also present preliminary test results for this measurement system and explain the discovered problems and possible solutions.
format article
author Zhuravlev Michael
Nemtcev Grigorii
Nagornyi Nikita
Meshchaninov Sergey
Rodionov Roman
Mironov Andrey
Zvonareva Anzhela
Mironova Ekaterina
Portone Sergey
author_facet Zhuravlev Michael
Nemtcev Grigorii
Nagornyi Nikita
Meshchaninov Sergey
Rodionov Roman
Mironov Andrey
Zvonareva Anzhela
Mironova Ekaterina
Portone Sergey
author_sort Zhuravlev Michael
title Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
title_short Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
title_full Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
title_fullStr Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
title_full_unstemmed Development of a real-time signal processing unit for diamond detectors of ITER Vertical Neutron Camera
title_sort development of a real-time signal processing unit for diamond detectors of iter vertical neutron camera
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/d1bbc67bc8914e86b0e014f9b053c460
work_keys_str_mv AT zhuravlevmichael developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT nemtcevgrigorii developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT nagornyinikita developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT meshchaninovsergey developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT rodionovroman developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT mironovandrey developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT zvonarevaanzhela developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT mironovaekaterina developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
AT portonesergey developmentofarealtimesignalprocessingunitfordiamonddetectorsofiterverticalneutroncamera
_version_ 1718381408026624000