Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

Mohamed Attia Ali Ahmed, Ahmed Shawkat Abdelhalim Ophthalmology Department, Faculty of Medicine, Minia University, Minia, EgyptCorrespondence: Mohamed Attia Ali Ahmed Email mohamedattia27@gmail.comPurpose: To evaluate variability in measured intraocular pressure (IOP) values when correlated with cen...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ahmed MAA, Abdelhalim AS
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/d22a717394bb48d1b489d2b5bbc53012
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d22a717394bb48d1b489d2b5bbc53012
record_format dspace
spelling oai:doaj.org-article:d22a717394bb48d1b489d2b5bbc530122021-12-02T13:35:45ZCorrected Intraocular Pressure Variability with Central Corneal Thickness Measurement1177-5483https://doaj.org/article/d22a717394bb48d1b489d2b5bbc530122020-12-01T00:00:00Zhttps://www.dovepress.com/corrected-intraocular-pressure-variability-with-central-corneal-thickn-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Mohamed Attia Ali Ahmed, Ahmed Shawkat Abdelhalim Ophthalmology Department, Faculty of Medicine, Minia University, Minia, EgyptCorrespondence: Mohamed Attia Ali Ahmed Email mohamedattia27@gmail.comPurpose: To evaluate variability in measured intraocular pressure (IOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools.Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35– 76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT).Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected IOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively).Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.Keywords: central corneal thickness, pachymeter, intraocular pressure, corneal thickness-corrected intraocular pressure, Goldmann applanation tonometry, anterior-segment optical coherence tomographyAhmed MAAAbdelhalim ASDove Medical Pressarticlecentral corneal thicknesspachymeterintraocular pressurecorneal thickness-corrected intraocular pressuregoldmann applanation tonometryanterior-segment optical coherence tomography.OphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 4501-4506 (2020)
institution DOAJ
collection DOAJ
language EN
topic central corneal thickness
pachymeter
intraocular pressure
corneal thickness-corrected intraocular pressure
goldmann applanation tonometry
anterior-segment optical coherence tomography.
Ophthalmology
RE1-994
spellingShingle central corneal thickness
pachymeter
intraocular pressure
corneal thickness-corrected intraocular pressure
goldmann applanation tonometry
anterior-segment optical coherence tomography.
Ophthalmology
RE1-994
Ahmed MAA
Abdelhalim AS
Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
description Mohamed Attia Ali Ahmed, Ahmed Shawkat Abdelhalim Ophthalmology Department, Faculty of Medicine, Minia University, Minia, EgyptCorrespondence: Mohamed Attia Ali Ahmed Email mohamedattia27@gmail.comPurpose: To evaluate variability in measured intraocular pressure (IOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools.Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35– 76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT).Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected IOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively).Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.Keywords: central corneal thickness, pachymeter, intraocular pressure, corneal thickness-corrected intraocular pressure, Goldmann applanation tonometry, anterior-segment optical coherence tomography
format article
author Ahmed MAA
Abdelhalim AS
author_facet Ahmed MAA
Abdelhalim AS
author_sort Ahmed MAA
title Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
title_short Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
title_full Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
title_fullStr Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
title_full_unstemmed Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
title_sort corrected intraocular pressure variability with central corneal thickness measurement
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/d22a717394bb48d1b489d2b5bbc53012
work_keys_str_mv AT ahmedmaa correctedintraocularpressurevariabilitywithcentralcornealthicknessmeasurement
AT abdelhalimas correctedintraocularpressurevariabilitywithcentralcornealthicknessmeasurement
_version_ 1718392702761959424