Designing and manufacturing a heat control system of X-ray tubes in multiple exposures
Objective: Over 1/3 to half of accurate medical diagnosis are based on x-ray examinations. The x-ray tube is the main part of a radiology set. X-ray production is a phenomenon with low efficiency and over 99.6% of the fast electrons energy changes to heat. This heat is also a limiting factor for the...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN FA |
Publicado: |
Babol University of Medical Sciences
2001
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d2652a8c805347b9bb0ff0d166bc6d0f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:d2652a8c805347b9bb0ff0d166bc6d0f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:d2652a8c805347b9bb0ff0d166bc6d0f2021-11-10T09:21:13ZDesigning and manufacturing a heat control system of X-ray tubes in multiple exposures1561-41072251-7170https://doaj.org/article/d2652a8c805347b9bb0ff0d166bc6d0f2001-10-01T00:00:00Zhttp://jbums.org/article-1-2845-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170Objective: Over 1/3 to half of accurate medical diagnosis are based on x-ray examinations. The x-ray tube is the main part of a radiology set. X-ray production is a phenomenon with low efficiency and over 99.6% of the fast electrons energy changes to heat. This heat is also a limiting factor for the system function. The aim of this study was to design and manufacture an automatic heat control system in radiology tubes for multiple exposures. These exposures are allowed with regard to overload system but inappropriate intervaling in exposures causes heat damages in anode. Methods: The hardware of system was designed and manufactured by using of micro-controller system. Its software was written by 8051 Franklin preview software package and on the basis of anode cooling chart data and installed on micro-controller by A1-11 system. Findings: The designed system can calculate and display anode heat at every moment. Functioning test in 100 experimental exposures showed a reliability of 99.92±0.07%. Conclusion: This system can be used as a suitable equipment in protecting and preventing radiology tubes against heat damages after frequent exposures.A Shabestani MonfaredH Nezamabadi PourA HashemoghliA Aliasghar ZadehBabol University of Medical Sciencesarticlex-ray tubeheat damagesanodemultiple exposuresMedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 3, Iss 4, Pp 7-10 (2001) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FA |
topic |
x-ray tube heat damages anode multiple exposures Medicine R Medicine (General) R5-920 |
spellingShingle |
x-ray tube heat damages anode multiple exposures Medicine R Medicine (General) R5-920 A Shabestani Monfared H Nezamabadi Pour A Hashemoghli A Aliasghar Zadeh Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
description |
Objective: Over 1/3 to half of accurate medical diagnosis are based on x-ray examinations. The x-ray tube is the main part of a radiology set. X-ray production is a phenomenon with low efficiency and over 99.6% of the fast electrons energy changes to heat. This heat is also a limiting factor for the system function. The aim of this study was to design and manufacture an automatic heat control system in radiology tubes for multiple exposures. These exposures are allowed with regard to overload system but inappropriate intervaling in exposures causes heat damages in anode. Methods: The hardware of system was designed and manufactured by using of micro-controller system. Its software was written by 8051 Franklin preview software package and on the basis of anode cooling chart data and installed on micro-controller by A1-11 system. Findings: The designed system can calculate and display anode heat at every moment. Functioning test in 100 experimental exposures showed a reliability of 99.92±0.07%. Conclusion: This system can be used as a suitable equipment in protecting and preventing radiology tubes against heat damages after frequent exposures. |
format |
article |
author |
A Shabestani Monfared H Nezamabadi Pour A Hashemoghli A Aliasghar Zadeh |
author_facet |
A Shabestani Monfared H Nezamabadi Pour A Hashemoghli A Aliasghar Zadeh |
author_sort |
A Shabestani Monfared |
title |
Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
title_short |
Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
title_full |
Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
title_fullStr |
Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
title_full_unstemmed |
Designing and manufacturing a heat control system of X-ray tubes in multiple exposures |
title_sort |
designing and manufacturing a heat control system of x-ray tubes in multiple exposures |
publisher |
Babol University of Medical Sciences |
publishDate |
2001 |
url |
https://doaj.org/article/d2652a8c805347b9bb0ff0d166bc6d0f |
work_keys_str_mv |
AT ashabestanimonfared designingandmanufacturingaheatcontrolsystemofxraytubesinmultipleexposures AT hnezamabadipour designingandmanufacturingaheatcontrolsystemofxraytubesinmultipleexposures AT ahashemoghli designingandmanufacturingaheatcontrolsystemofxraytubesinmultipleexposures AT aaliasgharzadeh designingandmanufacturingaheatcontrolsystemofxraytubesinmultipleexposures |
_version_ |
1718440141617364992 |