Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery
Hisato OhnoInouye Eye Hospital, Chiyoda-ku, Tokyo, JapanBackground: The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery.Methods: Twenty-three gauge vitrectomy was perform...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2011
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d319296f2ac243dca48ed3ba8c148edb |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:d319296f2ac243dca48ed3ba8c148edb |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:d319296f2ac243dca48ed3ba8c148edb2021-12-02T01:48:13ZCombined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery1177-54671177-5483https://doaj.org/article/d319296f2ac243dca48ed3ba8c148edb2011-08-01T00:00:00Zhttp://www.dovepress.com/combined-use-of-high-reflective-index-vitrectomy-meniscus-contact-lens-a8057https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Hisato OhnoInouye Eye Hospital, Chiyoda-ku, Tokyo, JapanBackground: The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery.Methods: Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as internal limiting membrane peeling was performed, only the HHV meniscus lens was used.Results: Advantages of this combination procedure include the ability to observe the peripheral fundus image, easy access to the posterior pole without exchange of the contact lens when needed, keeping the corneal surface wet covered by a contact lens, and the good view afforded during fluid–air exchange.Conclusion: Combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system is useful for vitreous surgery. It has the advantages of both contact and noncontact wide-angle viewing systems.Keywords: fundus, fluid–air, surgeryOhno HDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 1109-1111 (2011) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Ohno H Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
description |
Hisato OhnoInouye Eye Hospital, Chiyoda-ku, Tokyo, JapanBackground: The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery.Methods: Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as internal limiting membrane peeling was performed, only the HHV meniscus lens was used.Results: Advantages of this combination procedure include the ability to observe the peripheral fundus image, easy access to the posterior pole without exchange of the contact lens when needed, keeping the corneal surface wet covered by a contact lens, and the good view afforded during fluid–air exchange.Conclusion: Combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system is useful for vitreous surgery. It has the advantages of both contact and noncontact wide-angle viewing systems.Keywords: fundus, fluid–air, surgery |
format |
article |
author |
Ohno H |
author_facet |
Ohno H |
author_sort |
Ohno H |
title |
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
title_short |
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
title_full |
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
title_fullStr |
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
title_full_unstemmed |
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
title_sort |
combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery |
publisher |
Dove Medical Press |
publishDate |
2011 |
url |
https://doaj.org/article/d319296f2ac243dca48ed3ba8c148edb |
work_keys_str_mv |
AT ohnoh combineduseofhighreflectiveindexvitrectomymeniscuscontactlensandanoncontactwideangleviewingsysteminvitreoussurgery |
_version_ |
1718402926574043136 |