Dynamic strength analysis of the key components of the beam-type pumping unit with dynamic tracking balance

Aiming at the shortages of large reversing impact, high energy consumption and poor balance effect of conventional beam-type pumping unit, the design scheme of beam-type pumping unit with dynamic tracking balance is proposed. The load-displacement curves from on-site trial shows that pumping with d...

Full description

Saved in:
Bibliographic Details
Main Author: Bo Wang
Format: article
Language:EN
Published: Gruppo Italiano Frattura 2021
Subjects:
Online Access:https://doaj.org/article/d3c8b38cfc7e42b1bb270d7d3f086ff7
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Aiming at the shortages of large reversing impact, high energy consumption and poor balance effect of conventional beam-type pumping unit, the design scheme of beam-type pumping unit with dynamic tracking balance is proposed. The load-displacement curves from on-site trial shows that pumping with dynamic tracking balance has a better balance effect, and a production and power efficiency. According to the designed structure, the dynamic responses of the beam and connecting rods are analyzed. The results show that the maximum Mises stresses in the beam and connecting rod are 36.96 MPa and 27.83 MPa, respectively. The key components of designed beam-type pumping unit with dynamic tracking balance meet the requirement of strength.