Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite
Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospita...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d5ee6a2d07ba4aefb8592283fa3bf52f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:d5ee6a2d07ba4aefb8592283fa3bf52f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:d5ee6a2d07ba4aefb8592283fa3bf52f2021-12-02T06:46:22ZQuantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite1178-2013https://doaj.org/article/d5ee6a2d07ba4aefb8592283fa3bf52f2017-07-01T00:00:00Zhttps://www.dovepress.com/quantum-dots-based-lateral-flow-immunoassay-combined-with-image-analys-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE) with well clinical relevance to house dust mite (HDM) are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE Zhao YZhang QMeng QWu FZhang LTang YGuan YAn LDove Medical PressarticleLateral flow immunoassayQuantum dotsHouse dust miteIgEMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol Volume 12, Pp 4805-4812 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Lateral flow immunoassay Quantum dots House dust mite IgE Medicine (General) R5-920 |
spellingShingle |
Lateral flow immunoassay Quantum dots House dust mite IgE Medicine (General) R5-920 Zhao Y Zhang Q Meng Q Wu F Zhang L Tang Y Guan Y An L Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
description |
Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE) with well clinical relevance to house dust mite (HDM) are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE |
format |
article |
author |
Zhao Y Zhang Q Meng Q Wu F Zhang L Tang Y Guan Y An L |
author_facet |
Zhao Y Zhang Q Meng Q Wu F Zhang L Tang Y Guan Y An L |
author_sort |
Zhao Y |
title |
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
title_short |
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
title_full |
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
title_fullStr |
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
title_full_unstemmed |
Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite |
title_sort |
quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of ige antibody to mite |
publisher |
Dove Medical Press |
publishDate |
2017 |
url |
https://doaj.org/article/d5ee6a2d07ba4aefb8592283fa3bf52f |
work_keys_str_mv |
AT zhaoy quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT zhangq quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT mengq quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT wuf quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT zhangl quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT tangy quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT guany quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite AT anl quantumdotsbasedlateralflowimmunoassaycombinedwithimageanalysisforsemiquantitativedetectionofigeantibodytomite |
_version_ |
1718399782249037824 |