Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas

Janusz Skrzypecki,1,2 Iwona Grabska-Liberek,3 Maria Guszkowska,1 Justyna Izdebska,1 Jacek P Szaflik1 1Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland; 2Department of Experimental Physiology and Pathophysiology, Medical University of Warsaw, Warsaw, Poland; 3Department of Op...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Skrzypecki J, Grabska-Liberek I, Guszkowska M, Izdebska J, Szaflik JP
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/d612a0b6f77646258e216a85800af61d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d612a0b6f77646258e216a85800af61d
record_format dspace
spelling oai:doaj.org-article:d612a0b6f77646258e216a85800af61d2021-12-02T11:14:38ZImmersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas1177-5483https://doaj.org/article/d612a0b6f77646258e216a85800af61d2020-07-01T00:00:00Zhttps://www.dovepress.com/immersion-biometry-for-intraocular-lens-power-calculation-with-fourth--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Janusz Skrzypecki,1,2 Iwona Grabska-Liberek,3 Maria Guszkowska,1 Justyna Izdebska,1 Jacek P Szaflik1 1Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland; 2Department of Experimental Physiology and Pathophysiology, Medical University of Warsaw, Warsaw, Poland; 3Department of Ophthalmology, Medical Centre for Postgraduate Education, Warsaw, PolandCorrespondence: Janusz Skrzypecki Email jskrzypecki@wum.edu.plBackground: Fourth-generation formulas for intraocular lens power calculations, including the Barrett Universal II formula, the Olsen formula or the Holladay 2 formula, were thoroughly validated with optical biometry measurements. They precisely predict the effective lens position not only in normal eyes but also in eyes with unusual anatomy. However, in the setting of dense nuclear or posterior subcapsular cataracts, optical biometers fail to obtain accurate measurements and third-generation formulas, i.e. the Hoffer Q or the SRK/T, combined with ultrasound measurements are a method of choice. Considering that optical biometry was fine-tuned to immersion ultrasound, we hypothesize that fourth-generation formulas will yield precise intraocular lens power calculations with immersion ultrasound measurements.Methods: We retrospectively analyzed 50 eyes of 50 patients who underwent uneventful cataract surgery. All patients had intraocular lens power calculated based on immersion ultrasound measurements. Refractive error predictions were compared between third-generation formulas and fourth-generation formulas.Results: There were no statistically significant differences in the median absolute error between formulas. In the study, 86%, 88%, 86%, 84%, 88% and 80% of eyes were within 1 D of target refraction for the SRK/T, the Barrett II, the Hoffer Q, the Holladay 1, the Holladay 2 and the Olsen formula respectively.Conclusion: Fourth-generation formulas combined with immersion ultrasound produced similar results to third-generation formulas. However, the percentage of eyes within 1 D of target refraction remains inferior to previously reported results for optical biometry measurements.Keywords: intraocular lens, intraocular lens power, Barrett Universal formula, cataractSkrzypecki JGrabska-Liberek IGuszkowska MIzdebska JSzaflik JPDove Medical Pressarticleintraocular lensintraocular lens powerbarrett universal formulacataractOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 2159-2162 (2020)
institution DOAJ
collection DOAJ
language EN
topic intraocular lens
intraocular lens power
barrett universal formula
cataract
Ophthalmology
RE1-994
spellingShingle intraocular lens
intraocular lens power
barrett universal formula
cataract
Ophthalmology
RE1-994
Skrzypecki J
Grabska-Liberek I
Guszkowska M
Izdebska J
Szaflik JP
Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
description Janusz Skrzypecki,1,2 Iwona Grabska-Liberek,3 Maria Guszkowska,1 Justyna Izdebska,1 Jacek P Szaflik1 1Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland; 2Department of Experimental Physiology and Pathophysiology, Medical University of Warsaw, Warsaw, Poland; 3Department of Ophthalmology, Medical Centre for Postgraduate Education, Warsaw, PolandCorrespondence: Janusz Skrzypecki Email jskrzypecki@wum.edu.plBackground: Fourth-generation formulas for intraocular lens power calculations, including the Barrett Universal II formula, the Olsen formula or the Holladay 2 formula, were thoroughly validated with optical biometry measurements. They precisely predict the effective lens position not only in normal eyes but also in eyes with unusual anatomy. However, in the setting of dense nuclear or posterior subcapsular cataracts, optical biometers fail to obtain accurate measurements and third-generation formulas, i.e. the Hoffer Q or the SRK/T, combined with ultrasound measurements are a method of choice. Considering that optical biometry was fine-tuned to immersion ultrasound, we hypothesize that fourth-generation formulas will yield precise intraocular lens power calculations with immersion ultrasound measurements.Methods: We retrospectively analyzed 50 eyes of 50 patients who underwent uneventful cataract surgery. All patients had intraocular lens power calculated based on immersion ultrasound measurements. Refractive error predictions were compared between third-generation formulas and fourth-generation formulas.Results: There were no statistically significant differences in the median absolute error between formulas. In the study, 86%, 88%, 86%, 84%, 88% and 80% of eyes were within 1 D of target refraction for the SRK/T, the Barrett II, the Hoffer Q, the Holladay 1, the Holladay 2 and the Olsen formula respectively.Conclusion: Fourth-generation formulas combined with immersion ultrasound produced similar results to third-generation formulas. However, the percentage of eyes within 1 D of target refraction remains inferior to previously reported results for optical biometry measurements.Keywords: intraocular lens, intraocular lens power, Barrett Universal formula, cataract
format article
author Skrzypecki J
Grabska-Liberek I
Guszkowska M
Izdebska J
Szaflik JP
author_facet Skrzypecki J
Grabska-Liberek I
Guszkowska M
Izdebska J
Szaflik JP
author_sort Skrzypecki J
title Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
title_short Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
title_full Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
title_fullStr Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
title_full_unstemmed Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
title_sort immersion biometry for intraocular lens power calculation with fourth-generation formulas
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/d612a0b6f77646258e216a85800af61d
work_keys_str_mv AT skrzypeckij immersionbiometryforintraocularlenspowercalculationwithfourthgenerationformulas
AT grabskalibereki immersionbiometryforintraocularlenspowercalculationwithfourthgenerationformulas
AT guszkowskam immersionbiometryforintraocularlenspowercalculationwithfourthgenerationformulas
AT izdebskaj immersionbiometryforintraocularlenspowercalculationwithfourthgenerationformulas
AT szaflikjp immersionbiometryforintraocularlenspowercalculationwithfourthgenerationformulas
_version_ 1718396140695584768