Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length

Abstract The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q,...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ayoung Choi, Hyunggoo Kwon, Sohee Jeon
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/d69f199ed4c146ef9ebc5cddb9873550
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d69f199ed4c146ef9ebc5cddb9873550
record_format dspace
spelling oai:doaj.org-article:d69f199ed4c146ef9ebc5cddb98735502021-12-02T14:25:22ZAccuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length10.1038/s41598-021-86604-52045-2322https://doaj.org/article/d69f199ed4c146ef9ebc5cddb98735502021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-86604-5https://doaj.org/toc/2045-2322Abstract The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 ± 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 ± 0.22 D and 0.32 ± 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 ± 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P = 0.013), wider white-to-white (WTW; P < 0.001), and shorter AXL (P = 0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.Ayoung ChoiHyunggoo KwonSohee JeonNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Ayoung Choi
Hyunggoo Kwon
Sohee Jeon
Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
description Abstract The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 ± 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 ± 0.22 D and 0.32 ± 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 ± 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P = 0.013), wider white-to-white (WTW; P < 0.001), and shorter AXL (P = 0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.
format article
author Ayoung Choi
Hyunggoo Kwon
Sohee Jeon
author_facet Ayoung Choi
Hyunggoo Kwon
Sohee Jeon
author_sort Ayoung Choi
title Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
title_short Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
title_full Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
title_fullStr Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
title_full_unstemmed Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
title_sort accuracy of theoretical iol formulas for panoptix intraocular lens according to axial length
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/d69f199ed4c146ef9ebc5cddb9873550
work_keys_str_mv AT ayoungchoi accuracyoftheoreticaliolformulasforpanoptixintraocularlensaccordingtoaxiallength
AT hyunggookwon accuracyoftheoreticaliolformulasforpanoptixintraocularlensaccordingtoaxiallength
AT soheejeon accuracyoftheoreticaliolformulasforpanoptixintraocularlensaccordingtoaxiallength
_version_ 1718391399089438720