Improving mandibular reconstruction by using topology optimization, patient specific design and additive manufacturing?-A biomechanical comparison against miniplates on human specimen.
In this study, topology optimized, patient specific osteosynthesis plates (TOPOS-implants) are evaluated for the mandibular reconstruction using fibula segments. These shape optimized implants are compared to a standard treatment with miniplates (thickness: 1.0 mm, titanium grade 4) in biomechanical...
Guardado en:
Autores principales: | Jan J Lang, Mirjam Bastian, Peter Foehr, Michael Seebach, Jochen Weitz, Constantin von Deimling, Benedikt J Schwaiger, Carina M Micheler, Nikolas J Wilhelm, Christian U Grosse, Marco Kesting, Rainer Burgkart |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d7b005acd82c462bb1fc13bb328ebce3 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Ejemplares similares
-
Fine tuning of the side-to-side tenorrhaphy: A biomechanical study assessing different side-to-side suture techniques in a porcine tendon model.
por: Christina J Wilhelm, et al.
Publicado: (2021) -
Electromyographic Evaluation of Mandibular Biomechanic
por: Coelho-Ferraz,Maria Julia P, et al.
Publicado: (2009) -
Radiographic and Clinical Evaluations of the Zygomatico-maxillary Complex Fractures Treated by 2.0 Miniplates System
por: Bassi,Ana Paula Farnezi, et al.
Publicado: (2014) -
Design and manufacturing optimization of epoxy-based adhesive specimens for multiaxial tests
por: Michael Wentingmann, et al.
Publicado: (2021) -
Physical limits to biomechanical sensing in disordered fibre networks
por: Farzan Beroz, et al.
Publicado: (2017)