Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method

To record Roentgen image on sillenite-type crystals while charging in a corona discharge field, a device has been performed. The resolution not less than 10 pairs of lines per mm, the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the exposure le...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dementiev, Igor, Maximov, Eugen, Pocatilov, Evghenii, Taracanova, Larisa
Formato: article
Lenguaje:EN
Publicado: D.Ghitu Institute of Electronic Engineering and Nanotechnologies 2005
Materias:
Acceso en línea:https://doaj.org/article/d7d3ab383ddd45ca9c9bc6c0aad9dbe8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d7d3ab383ddd45ca9c9bc6c0aad9dbe8
record_format dspace
spelling oai:doaj.org-article:d7d3ab383ddd45ca9c9bc6c0aad9dbe82021-11-21T12:13:21ZRoentgen image recording on sillenite-type electrooptical crystals by electrophotographic method2537-63651810-648Xhttps://doaj.org/article/d7d3ab383ddd45ca9c9bc6c0aad9dbe82005-01-01T00:00:00Zhttps://mjps.nanotech.md/archive/2005/article/3057https://doaj.org/toc/1810-648Xhttps://doaj.org/toc/2537-6365To record Roentgen image on sillenite-type crystals while charging in a corona discharge field, a device has been performed. The resolution not less than 10 pairs of lines per mm, the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the exposure length of 0.6 s were obtained using Bi12GeO20 crystal. The device survives more than 104 of writing-erase cycles. From the sensitivity point of view, the considered registration is just as good as X-Ray films used for radiography and dosimetry. Dementiev, IgorMaximov, EugenPocatilov, EvgheniiTaracanova, LarisaD.Ghitu Institute of Electronic Engineering and NanotechnologiesarticlePhysicsQC1-999ElectronicsTK7800-8360ENMoldavian Journal of the Physical Sciences, Vol 4, Iss 1, Pp 64-68 (2005)
institution DOAJ
collection DOAJ
language EN
topic Physics
QC1-999
Electronics
TK7800-8360
spellingShingle Physics
QC1-999
Electronics
TK7800-8360
Dementiev, Igor
Maximov, Eugen
Pocatilov, Evghenii
Taracanova, Larisa
Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
description To record Roentgen image on sillenite-type crystals while charging in a corona discharge field, a device has been performed. The resolution not less than 10 pairs of lines per mm, the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the exposure length of 0.6 s were obtained using Bi12GeO20 crystal. The device survives more than 104 of writing-erase cycles. From the sensitivity point of view, the considered registration is just as good as X-Ray films used for radiography and dosimetry.
format article
author Dementiev, Igor
Maximov, Eugen
Pocatilov, Evghenii
Taracanova, Larisa
author_facet Dementiev, Igor
Maximov, Eugen
Pocatilov, Evghenii
Taracanova, Larisa
author_sort Dementiev, Igor
title Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
title_short Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
title_full Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
title_fullStr Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
title_full_unstemmed Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
title_sort roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method
publisher D.Ghitu Institute of Electronic Engineering and Nanotechnologies
publishDate 2005
url https://doaj.org/article/d7d3ab383ddd45ca9c9bc6c0aad9dbe8
work_keys_str_mv AT dementievigor roentgenimagerecordingonsillenitetypeelectroopticalcrystalsbyelectrophotographicmethod
AT maximoveugen roentgenimagerecordingonsillenitetypeelectroopticalcrystalsbyelectrophotographicmethod
AT pocatilovevghenii roentgenimagerecordingonsillenitetypeelectroopticalcrystalsbyelectrophotographicmethod
AT taracanovalarisa roentgenimagerecordingonsillenitetypeelectroopticalcrystalsbyelectrophotographicmethod
_version_ 1718419153624236032