THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE

Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulati...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: G. V. Bezprozvannych, I. A. Mirchuk
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2017
Materias:
Acceso en línea:https://doaj.org/article/d7dbc929f63d4369b0c900f8666a6da7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d7dbc929f63d4369b0c900f8666a6da7
record_format dspace
spelling oai:doaj.org-article:d7dbc929f63d4369b0c900f8666a6da72021-12-02T18:18:19ZTHE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE10.20998/2074-272X.2017.5.082074-272X2309-3404https://doaj.org/article/d7dbc929f63d4369b0c900f8666a6da72017-10-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2017.5.08/107217https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulating materials. Purpose. Substantiation of the possibility of unshielded cables on the basis of unshielded twisted pairs with thermoplastic polyethylene insulation in PVC protective jacket in conditions of high humidity and high operating temperatures on the basis of the results of accelerated aging. Methodology. The cycle of aging under conditions of increased humidity is performed for 336 hours. Then the sample was under natural drying conditions for 1440 hours. Thermal aging in a thermostat at 90 °C was carried out in two stages: first – for 206 hours, the second – for 260 hours. In the initial state and after accelerated aging, measurements of the capacitance and tangent of the dielectric loss angle of all the insulating gaps at frequencies of 100 Hz, 1 and 10 kHz were performed. Results. According to the results of accelerated aging under conditions of high humidity and temperature, it is established that the design of an unshielded cable based on unshielded twisted pairs with thermoplastic polyethylene insulation in a protective coating based on PVC-plastic is resistant to external influencing factors. Practical value. The prolonged holding at temperature of 90 °C is equivalent to operation at temperature of 40 °C for 6.8 years. At higher operating temperatures, the lifetime of the cable is significantly reduced.G. V. BezprozvannychI. A. MirchukNational Technical University "Kharkiv Polytechnic Institute"articlecables based on twisted pairs for shipbuildingaccelerated aginghygroscopic moisteningthermal agingpartial capacitancetangent of the dielectric loss angleservice lifeElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 5, Pp 51-54 (2017)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic cables based on twisted pairs for shipbuilding
accelerated aging
hygroscopic moistening
thermal aging
partial capacitance
tangent of the dielectric loss angle
service life
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle cables based on twisted pairs for shipbuilding
accelerated aging
hygroscopic moistening
thermal aging
partial capacitance
tangent of the dielectric loss angle
service life
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
G. V. Bezprozvannych
I. A. Mirchuk
THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
description Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulating materials. Purpose. Substantiation of the possibility of unshielded cables on the basis of unshielded twisted pairs with thermoplastic polyethylene insulation in PVC protective jacket in conditions of high humidity and high operating temperatures on the basis of the results of accelerated aging. Methodology. The cycle of aging under conditions of increased humidity is performed for 336 hours. Then the sample was under natural drying conditions for 1440 hours. Thermal aging in a thermostat at 90 °C was carried out in two stages: first – for 206 hours, the second – for 260 hours. In the initial state and after accelerated aging, measurements of the capacitance and tangent of the dielectric loss angle of all the insulating gaps at frequencies of 100 Hz, 1 and 10 kHz were performed. Results. According to the results of accelerated aging under conditions of high humidity and temperature, it is established that the design of an unshielded cable based on unshielded twisted pairs with thermoplastic polyethylene insulation in a protective coating based on PVC-plastic is resistant to external influencing factors. Practical value. The prolonged holding at temperature of 90 °C is equivalent to operation at temperature of 40 °C for 6.8 years. At higher operating temperatures, the lifetime of the cable is significantly reduced.
format article
author G. V. Bezprozvannych
I. A. Mirchuk
author_facet G. V. Bezprozvannych
I. A. Mirchuk
author_sort G. V. Bezprozvannych
title THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
title_short THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
title_full THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
title_fullStr THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
title_full_unstemmed THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
title_sort evaluation of possibility of normal operation of cables based on twisted pairs with pvc jacket under the conditions of high humidity and temperature
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2017
url https://doaj.org/article/d7dbc929f63d4369b0c900f8666a6da7
work_keys_str_mv AT gvbezprozvannych theevaluationofpossibilityofnormaloperationofcablesbasedontwistedpairswithpvcjacketundertheconditionsofhighhumidityandtemperature
AT iamirchuk theevaluationofpossibilityofnormaloperationofcablesbasedontwistedpairswithpvcjacketundertheconditionsofhighhumidityandtemperature
AT gvbezprozvannych evaluationofpossibilityofnormaloperationofcablesbasedontwistedpairswithpvcjacketundertheconditionsofhighhumidityandtemperature
AT iamirchuk evaluationofpossibilityofnormaloperationofcablesbasedontwistedpairswithpvcjacketundertheconditionsofhighhumidityandtemperature
_version_ 1718378302106763264