Removal Turbidity of Water by Application of Electromagnetic Field Technology

Human and which serves to preserve the resource at the science forefront. Water of electromagnetic is old but addressed to popular the quantity of contaminants in a new way. The current study presents results related to the influence of an electromagnetic field (EMF) on synthetic water with Al2Si2O5...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Maryam Jawad Abdulhasan, Nassrin Jassim Hussien Al-Mansori, Mohsin J. Nasir
Formato: article
Lenguaje:EN
Publicado: Polish Society of Ecological Engineering (PTIE) 2022
Materias:
Acceso en línea:https://doaj.org/article/d83d3743f57f4751910ff2e87028047d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d83d3743f57f4751910ff2e87028047d
record_format dspace
spelling oai:doaj.org-article:d83d3743f57f4751910ff2e87028047d2021-12-01T13:20:42ZRemoval Turbidity of Water by Application of Electromagnetic Field Technology2299-899310.12911/22998993/143751https://doaj.org/article/d83d3743f57f4751910ff2e87028047d2022-01-01T00:00:00Zhttp://www.jeeng.net/Removal-Turbidity-of-Water-by-Application-of-Electromagnetic-Field-Technology,143751,0,2.htmlhttps://doaj.org/toc/2299-8993Human and which serves to preserve the resource at the science forefront. Water of electromagnetic is old but addressed to popular the quantity of contaminants in a new way. The current study presents results related to the influence of an electromagnetic field (EMF) on synthetic water with Al2Si2O5(OH)4 (represented by Turbidity). The impact of an EMF as the only factor or as an intensifying element in stainless steel packing systems that limits pollutant concentrations in the treated water was analyses. The system that combined simultaneously stainless steel filling was most efficient. The electromagnetic treatment unit was designed and constructed for testing the treatment of syntheses water having turbidity. The influence of two variables on the efficiency of contaminant elimination during the function of the electromagnetic treating unit was checked. A significant dependence between the kind of system used reactor diameter and number of electrical coil windings were observed. The results showed that the PH values remain constant with EMF. The performance of the unit is determined by turbidity, the result shows greatest efficiency removal with 99.99% at the minimum diameter (2.54 cm), 99.99% in three reactors with three different numbers of coil turns.Maryam Jawad AbdulhasanNassrin Jassim Hussien Al-MansoriMohsin J. NasirPolish Society of Ecological Engineering (PTIE)articlewater treatmentsteel fillingelectromagnetic fieldturbidity removalEnvironmental technology. Sanitary engineeringTD1-1066Environmental sciencesGE1-350ENJournal of Ecological Engineering, Vol 23, Iss 1, Pp 51-54 (2022)
institution DOAJ
collection DOAJ
language EN
topic water treatment
steel filling
electromagnetic field
turbidity removal
Environmental technology. Sanitary engineering
TD1-1066
Environmental sciences
GE1-350
spellingShingle water treatment
steel filling
electromagnetic field
turbidity removal
Environmental technology. Sanitary engineering
TD1-1066
Environmental sciences
GE1-350
Maryam Jawad Abdulhasan
Nassrin Jassim Hussien Al-Mansori
Mohsin J. Nasir
Removal Turbidity of Water by Application of Electromagnetic Field Technology
description Human and which serves to preserve the resource at the science forefront. Water of electromagnetic is old but addressed to popular the quantity of contaminants in a new way. The current study presents results related to the influence of an electromagnetic field (EMF) on synthetic water with Al2Si2O5(OH)4 (represented by Turbidity). The impact of an EMF as the only factor or as an intensifying element in stainless steel packing systems that limits pollutant concentrations in the treated water was analyses. The system that combined simultaneously stainless steel filling was most efficient. The electromagnetic treatment unit was designed and constructed for testing the treatment of syntheses water having turbidity. The influence of two variables on the efficiency of contaminant elimination during the function of the electromagnetic treating unit was checked. A significant dependence between the kind of system used reactor diameter and number of electrical coil windings were observed. The results showed that the PH values remain constant with EMF. The performance of the unit is determined by turbidity, the result shows greatest efficiency removal with 99.99% at the minimum diameter (2.54 cm), 99.99% in three reactors with three different numbers of coil turns.
format article
author Maryam Jawad Abdulhasan
Nassrin Jassim Hussien Al-Mansori
Mohsin J. Nasir
author_facet Maryam Jawad Abdulhasan
Nassrin Jassim Hussien Al-Mansori
Mohsin J. Nasir
author_sort Maryam Jawad Abdulhasan
title Removal Turbidity of Water by Application of Electromagnetic Field Technology
title_short Removal Turbidity of Water by Application of Electromagnetic Field Technology
title_full Removal Turbidity of Water by Application of Electromagnetic Field Technology
title_fullStr Removal Turbidity of Water by Application of Electromagnetic Field Technology
title_full_unstemmed Removal Turbidity of Water by Application of Electromagnetic Field Technology
title_sort removal turbidity of water by application of electromagnetic field technology
publisher Polish Society of Ecological Engineering (PTIE)
publishDate 2022
url https://doaj.org/article/d83d3743f57f4751910ff2e87028047d
work_keys_str_mv AT maryamjawadabdulhasan removalturbidityofwaterbyapplicationofelectromagneticfieldtechnology
AT nassrinjassimhussienalmansori removalturbidityofwaterbyapplicationofelectromagneticfieldtechnology
AT mohsinjnasir removalturbidityofwaterbyapplicationofelectromagneticfieldtechnology
_version_ 1718405143768072192