Determination of X-ray detection limit and applications in perovskite X-ray detectors
The limit of X-ray detection is an important figure of merit for X-ray detectors, yet the suitability of method adopted from Currie’s 1968 paper and the following international standard is in doubt. Here, the authors propose a statistical model that correlates dark current and photo-current, show ho...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d8842a82eb454b8599e66e504c1f06e4 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:d8842a82eb454b8599e66e504c1f06e4 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:d8842a82eb454b8599e66e504c1f06e42021-12-02T17:41:07ZDetermination of X-ray detection limit and applications in perovskite X-ray detectors10.1038/s41467-021-25648-72041-1723https://doaj.org/article/d8842a82eb454b8599e66e504c1f06e42021-09-01T00:00:00Zhttps://doi.org/10.1038/s41467-021-25648-7https://doaj.org/toc/2041-1723The limit of X-ray detection is an important figure of merit for X-ray detectors, yet the suitability of method adopted from Currie’s 1968 paper and the following international standard is in doubt. Here, the authors propose a statistical model that correlates dark current and photo-current, show how it can be used to determine detection limit.Lei PanShreetu ShresthaNeil TaylorWanyi NieLei R. CaoNature PortfolioarticleScienceQENNature Communications, Vol 12, Iss 1, Pp 1-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Science Q |
spellingShingle |
Science Q Lei Pan Shreetu Shrestha Neil Taylor Wanyi Nie Lei R. Cao Determination of X-ray detection limit and applications in perovskite X-ray detectors |
description |
The limit of X-ray detection is an important figure of merit for X-ray detectors, yet the suitability of method adopted from Currie’s 1968 paper and the following international standard is in doubt. Here, the authors propose a statistical model that correlates dark current and photo-current, show how it can be used to determine detection limit. |
format |
article |
author |
Lei Pan Shreetu Shrestha Neil Taylor Wanyi Nie Lei R. Cao |
author_facet |
Lei Pan Shreetu Shrestha Neil Taylor Wanyi Nie Lei R. Cao |
author_sort |
Lei Pan |
title |
Determination of X-ray detection limit and applications in perovskite X-ray detectors |
title_short |
Determination of X-ray detection limit and applications in perovskite X-ray detectors |
title_full |
Determination of X-ray detection limit and applications in perovskite X-ray detectors |
title_fullStr |
Determination of X-ray detection limit and applications in perovskite X-ray detectors |
title_full_unstemmed |
Determination of X-ray detection limit and applications in perovskite X-ray detectors |
title_sort |
determination of x-ray detection limit and applications in perovskite x-ray detectors |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/d8842a82eb454b8599e66e504c1f06e4 |
work_keys_str_mv |
AT leipan determinationofxraydetectionlimitandapplicationsinperovskitexraydetectors AT shreetushrestha determinationofxraydetectionlimitandapplicationsinperovskitexraydetectors AT neiltaylor determinationofxraydetectionlimitandapplicationsinperovskitexraydetectors AT wanyinie determinationofxraydetectionlimitandapplicationsinperovskitexraydetectors AT leircao determinationofxraydetectionlimitandapplicationsinperovskitexraydetectors |
_version_ |
1718379731013861376 |