Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber

Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour mode...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Nurhaslina Hasan, Nur Fatihah Ronny Sham, Muhammad Khalis Abdul Karim, Syed Baharom Syed Ahmad Fuad, Narimah Abdul Hamid Hasani, Effat Omar, Mohammad Johari Ibahim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d8b27a3ac16045e485f79ca42c49abdb
record_format dspace
spelling oai:doaj.org-article:d8b27a3ac16045e485f79ca42c49abdb2021-12-02T16:14:10ZDevelopment of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber10.1038/s41598-021-93964-52045-2322https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb2021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-93964-5https://doaj.org/toc/2045-2322Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites.Nurhaslina HasanNur Fatihah Ronny ShamMuhammad Khalis Abdul KarimSyed Baharom Syed Ahmad FuadNarimah Abdul Hamid HasaniEffat OmarMohammad Johari IbahimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Nurhaslina Hasan
Nur Fatihah Ronny Sham
Muhammad Khalis Abdul Karim
Syed Baharom Syed Ahmad Fuad
Narimah Abdul Hamid Hasani
Effat Omar
Mohammad Johari Ibahim
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
description Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites.
format article
author Nurhaslina Hasan
Nur Fatihah Ronny Sham
Muhammad Khalis Abdul Karim
Syed Baharom Syed Ahmad Fuad
Narimah Abdul Hamid Hasani
Effat Omar
Mohammad Johari Ibahim
author_facet Nurhaslina Hasan
Nur Fatihah Ronny Sham
Muhammad Khalis Abdul Karim
Syed Baharom Syed Ahmad Fuad
Narimah Abdul Hamid Hasani
Effat Omar
Mohammad Johari Ibahim
author_sort Nurhaslina Hasan
title Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
title_short Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
title_full Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
title_fullStr Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
title_full_unstemmed Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
title_sort development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb
work_keys_str_mv AT nurhaslinahasan developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT nurfatihahronnysham developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT muhammadkhalisabdulkarim developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT syedbaharomsyedahmadfuad developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT narimahabdulhamidhasani developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT effatomar developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
AT mohammadjohariibahim developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber
_version_ 1718384379417329664