Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber
Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour mode...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:d8b27a3ac16045e485f79ca42c49abdb |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:d8b27a3ac16045e485f79ca42c49abdb2021-12-02T16:14:10ZDevelopment of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber10.1038/s41598-021-93964-52045-2322https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb2021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-93964-5https://doaj.org/toc/2045-2322Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites.Nurhaslina HasanNur Fatihah Ronny ShamMuhammad Khalis Abdul KarimSyed Baharom Syed Ahmad FuadNarimah Abdul Hamid HasaniEffat OmarMohammad Johari IbahimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Nurhaslina Hasan Nur Fatihah Ronny Sham Muhammad Khalis Abdul Karim Syed Baharom Syed Ahmad Fuad Narimah Abdul Hamid Hasani Effat Omar Mohammad Johari Ibahim Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
description |
Abstract We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites. |
format |
article |
author |
Nurhaslina Hasan Nur Fatihah Ronny Sham Muhammad Khalis Abdul Karim Syed Baharom Syed Ahmad Fuad Narimah Abdul Hamid Hasani Effat Omar Mohammad Johari Ibahim |
author_facet |
Nurhaslina Hasan Nur Fatihah Ronny Sham Muhammad Khalis Abdul Karim Syed Baharom Syed Ahmad Fuad Narimah Abdul Hamid Hasani Effat Omar Mohammad Johari Ibahim |
author_sort |
Nurhaslina Hasan |
title |
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
title_short |
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
title_full |
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
title_fullStr |
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
title_full_unstemmed |
Development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
title_sort |
development of custom lead shield and strainer for targeted irradiation for mice in the gamma cell chamber |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/d8b27a3ac16045e485f79ca42c49abdb |
work_keys_str_mv |
AT nurhaslinahasan developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT nurfatihahronnysham developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT muhammadkhalisabdulkarim developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT syedbaharomsyedahmadfuad developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT narimahabdulhamidhasani developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT effatomar developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber AT mohammadjohariibahim developmentofcustomleadshieldandstrainerfortargetedirradiationformiceinthegammacellchamber |
_version_ |
1718384379417329664 |