HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women

Iodine is an essential component for fetal neurodevelopment and maternal thyroid function. Urine iodine is the most widely used indicator of iodine status. In this study, a novel validated ion-pair HPLC–UV method was developed to measure iodine concentration in clinical samples. A sodium thiosulfate...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Aniceta A. Mikulska, Dorota Filipowicz, Franciszek K. Główka, Ewelina Szczepanek-Parulska, Marek Ruchała, Michał Bartecki, Marta Karaźniewicz-Łada
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/d9025bc5e8134fccbdbfa4097c7f8c02
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:d9025bc5e8134fccbdbfa4097c7f8c02
record_format dspace
spelling oai:doaj.org-article:d9025bc5e8134fccbdbfa4097c7f8c022021-11-25T18:27:20ZHPLC Analysis of the Urinary Iodine Concentration in Pregnant Women10.3390/molecules262267971420-3049https://doaj.org/article/d9025bc5e8134fccbdbfa4097c7f8c022021-11-01T00:00:00Zhttps://www.mdpi.com/1420-3049/26/22/6797https://doaj.org/toc/1420-3049Iodine is an essential component for fetal neurodevelopment and maternal thyroid function. Urine iodine is the most widely used indicator of iodine status. In this study, a novel validated ion-pair HPLC–UV method was developed to measure iodine concentration in clinical samples. A sodium thiosulfate solution was added to the urine sample to convert the total free iodine to iodide. Chromatographic separation was achieved in a Pursuit XRs C8 column. The mobile phase consisted of acetonitrile and a water phase containing 18-crown-6-ether, octylamine and sodium dihydrogen phosphate. Validation parameters, such as accuracy, precision, limits of detection and quantification, linearity and stability, were determined. Urinary samples from pregnant women were used to complete the validation and confirm the method’s applicability. In the studied population of 93 pregnant women, the median UIC was lower in the group without iodine supplementation (117 µg/L, confidence interval (%CI): 95; 138) than in the supplement group (133 µg/L, %CI: 109; 157). In conclusion, the newly established ion-pair HPLC–UV method was adequately precise, accurate and fulfilled validation the criteria for analyzing compounds in biological fluids. The method is less complicated and expensive than other frequently used assays and permits the identification of the iodine-deficient subjects.Aniceta A. MikulskaDorota FilipowiczFranciszek K. GłówkaEwelina Szczepanek-ParulskaMarek RuchałaMichał BarteckiMarta Karaźniewicz-ŁadaMDPI AGarticleion-pair HPLC–UV methodvalidationin vivo applicationiodine supplementationpregnancyOrganic chemistryQD241-441ENMolecules, Vol 26, Iss 6797, p 6797 (2021)
institution DOAJ
collection DOAJ
language EN
topic ion-pair HPLC–UV method
validation
in vivo application
iodine supplementation
pregnancy
Organic chemistry
QD241-441
spellingShingle ion-pair HPLC–UV method
validation
in vivo application
iodine supplementation
pregnancy
Organic chemistry
QD241-441
Aniceta A. Mikulska
Dorota Filipowicz
Franciszek K. Główka
Ewelina Szczepanek-Parulska
Marek Ruchała
Michał Bartecki
Marta Karaźniewicz-Łada
HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
description Iodine is an essential component for fetal neurodevelopment and maternal thyroid function. Urine iodine is the most widely used indicator of iodine status. In this study, a novel validated ion-pair HPLC–UV method was developed to measure iodine concentration in clinical samples. A sodium thiosulfate solution was added to the urine sample to convert the total free iodine to iodide. Chromatographic separation was achieved in a Pursuit XRs C8 column. The mobile phase consisted of acetonitrile and a water phase containing 18-crown-6-ether, octylamine and sodium dihydrogen phosphate. Validation parameters, such as accuracy, precision, limits of detection and quantification, linearity and stability, were determined. Urinary samples from pregnant women were used to complete the validation and confirm the method’s applicability. In the studied population of 93 pregnant women, the median UIC was lower in the group without iodine supplementation (117 µg/L, confidence interval (%CI): 95; 138) than in the supplement group (133 µg/L, %CI: 109; 157). In conclusion, the newly established ion-pair HPLC–UV method was adequately precise, accurate and fulfilled validation the criteria for analyzing compounds in biological fluids. The method is less complicated and expensive than other frequently used assays and permits the identification of the iodine-deficient subjects.
format article
author Aniceta A. Mikulska
Dorota Filipowicz
Franciszek K. Główka
Ewelina Szczepanek-Parulska
Marek Ruchała
Michał Bartecki
Marta Karaźniewicz-Łada
author_facet Aniceta A. Mikulska
Dorota Filipowicz
Franciszek K. Główka
Ewelina Szczepanek-Parulska
Marek Ruchała
Michał Bartecki
Marta Karaźniewicz-Łada
author_sort Aniceta A. Mikulska
title HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
title_short HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
title_full HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
title_fullStr HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
title_full_unstemmed HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women
title_sort hplc analysis of the urinary iodine concentration in pregnant women
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/d9025bc5e8134fccbdbfa4097c7f8c02
work_keys_str_mv AT anicetaamikulska hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT dorotafilipowicz hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT franciszekkgłowka hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT ewelinaszczepanekparulska hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT marekruchała hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT michałbartecki hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
AT martakarazniewiczłada hplcanalysisoftheurinaryiodineconcentrationinpregnantwomen
_version_ 1718411162301759488